Literature DB >> 23021521

Membrane bioreactor fouling behaviour assessment through principal component analysis and fuzzy clustering.

Thomas Maere1, Kris Villez, Stefano Marsili-Libelli, Wouter Naessens, Ingmar Nopens.   

Abstract

Adequate membrane bioreactor operation requires frequent evaluation of the membrane state. A data-driven approach based on principal component analysis (PCA) and fuzzy clustering extracting the necessary monitoring information solely out of transmembrane pressure data was investigated for this purpose. Out of three tested PCA techniques the two functional methods proved useful to cope with noise and outliers as opposed to the common standard PCA, while all of them presented similar capabilities for revealing data trends and patterns. The expert functional PCA approach enabled linking the two major trends in the data to reversible fouling and irreversible fouling. The B-splines approach provided a more objective way for functional representation of the data set but its complexity did not appear justified by better results. The fuzzy clustering algorithm, applied after PCA, was successful in recognizing the data trends and placing the cluster centres in meaningful positions, as such supporting data analysis. However, the algorithm did not allow a correct classification of all data. Factor analysis was used instead, exploiting the linearity of the observed two dimensional trends, to completely split the reversible and irreversible fouling effects and classify the data in a more pragmatic approach. Overall, the tested techniques appeared useful and can serve as the basis for automatic membrane fouling monitoring and control.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Mesh:

Substances:

Year:  2012        PMID: 23021521     DOI: 10.1016/j.watres.2012.08.027

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  3 in total

1.  Model-based analysis of the effect of different operating conditions on fouling mechanisms in a membrane bioreactor.

Authors:  Gianpaolo Sabia; Marco Ferraris; Alessandro Spagni
Journal:  Environ Sci Pollut Res Int       Date:  2015-09-17       Impact factor: 4.223

2.  Effect of sudden addition of PCE and bioreactor coupling to ZVI filters on performance of fluidized bed bioreactors operated in simultaneous electron acceptor modes.

Authors:  C U Moreno-Medina; Hector M Poggi-Varaldo; L Breton-Deval; N Rinderknecht-Seijas
Journal:  Environ Sci Pollut Res Int       Date:  2016-08-08       Impact factor: 4.223

3.  Visual tool for real-time monitoring of membrane fouling via Raman spectroscopy and process model based on principal component analysis.

Authors:  Tiina Virtanen; Satu-Pia Reinikainen; Jussi Lahti; Mika Mänttäri; Mari Kallioinen
Journal:  Sci Rep       Date:  2018-07-23       Impact factor: 4.379