Literature DB >> 23021176

Stress shielding around radial head prostheses.

Cholawish Chanlalit1, Dave R Shukla, James S Fitzsimmons, Kai-Nan An, Shawn W O'Driscoll.   

Abstract

PURPOSE: Stress shielding is known to occur around rigidly fixed implants. We hypothesized that stress shielding around radial head prostheses is common but nonprogressive. In this study, we present a classification scheme to support our radiographic observations.
METHODS: We reviewed charts and radiographs of 86 cases from 79 patients with radial head implants from both primary and revision surgeries between 1999 and 2009. Exclusion criteria included infection, loosening, or follow-up of less than 12 months. We classified stress shielding as: I, cortical thinning; II, partially (IIa) or circumferentially (IIb) exposed stem; and III, impending mechanical failure.
RESULTS: Of 26 well-fixed stems, 17 (63%) demonstrated stress shielding: I = 2, II = 15 (IIa = 12, IIb = 3), and III = 0. We saw stress shielding with all stem types: cemented or noncemented; long or short; and straight, curved, or tapered. The only significant difference was that stems implanted into the radial shaft had less stress shielding than stems implanted into the neck or tuberosity (P = .03). The average follow-up was 33 months (range, 13-70 mo). Stress shielding was detectable by an average of 11 months (range, 1-15 mo). The pattern of bone loss was similar in 16 of 17 cases (94%), starting on the outer periosteal cortex. The 3 cases with circumferential exposure of the stem (stage IIb) averaged 2.6 mm (range, 1-4 mm) of exposed stem. Stress shielding never extended to the bicipital tuberosity, and there were no cases of impending mechanical failure.
CONCLUSIONS: Stress shielding around radial head prostheses is common, regardless of stem design. However, it is typically minor, nonprogressive, and of questionable clinical consequence. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.
Copyright © 2012 American Society for Surgery of the Hand. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23021176     DOI: 10.1016/j.jhsa.2012.06.020

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  15 in total

1.  Short to midterm outcomes of one hundred and seventy one MoPyC radial head prostheses: meta-analysis.

Authors:  Pierre Laumonerie; Meagan E Tibbo; Panagiotis Kerezoudis; Marc Olivier Gauci; Nicolas Reina; Nicolas Bonnevialle; Pierre Mansat
Journal:  Int Orthop       Date:  2018-07-30       Impact factor: 3.075

Review 2.  [Primary radial head arthroplasty in trauma : Complications].

Authors:  K Schmidt-Horlohé; S Buschbeck; D Wincheringer; M Weißenberger; R Hoffmann
Journal:  Orthopade       Date:  2016-10       Impact factor: 1.087

3.  Tight-fitting radial head prosthesis: does stem size help prevent painful loosening?

Authors:  Pierre Laumonerie; Nicolas Reina; Claudia Gutierrez; Stephanie Delclaux; Meagan E Tibbo; Nicolas Bonnevialle; Pierre Mansat
Journal:  Int Orthop       Date:  2017-09-21       Impact factor: 3.075

Review 4.  Radial head fractures.

Authors:  R P van Riet; Mpj van den Bekerom; A Van Tongel; C Spross; R Barco; A C Watts
Journal:  Shoulder Elbow       Date:  2019-09-25

Review 5.  Complications of radial head prostheses.

Authors:  Stéphanie Delclaux; Julie Lebon; Amélie Faraud; Julien Toulemonde; Nicolas Bonnevialle; Bertrand Coulet; Pierre Mansat
Journal:  Int Orthop       Date:  2015-02-06       Impact factor: 3.075

6.  Survivorship of anatomic press-fit short-stem radial head replacement with a pyrocarbon bearing.

Authors:  Aparna I Viswanath; Adam C Watts
Journal:  Shoulder Elbow       Date:  2021-06-17

Review 7.  Laser Sintering Approaches for Bone Tissue Engineering.

Authors:  Jeremy N DiNoro; Naomi C Paxton; Jacob Skewes; Zhilian Yue; Philip M Lewis; Robert G Thompson; Stephen Beirne; Maria A Woodruff; Gordon G Wallace
Journal:  Polymers (Basel)       Date:  2022-06-09       Impact factor: 4.967

Review 8.  Midterm outcomes of 146 EVOLVE Proline modular radial head prostheses: a systematic review.

Authors:  Pierre Laumonerie; Maroun Raad; Meagan E Tibbo; Panagiotis Kerezoudis; Nicolas Bonnevialle; Pierre Mansat
Journal:  Shoulder Elbow       Date:  2019-05-19

Review 9.  Biodegradable Materials for Bone Repair and Tissue Engineering Applications.

Authors:  Zeeshan Sheikh; Shariq Najeeb; Zohaib Khurshid; Vivek Verma; Haroon Rashid; Michael Glogauer
Journal:  Materials (Basel)       Date:  2015-08-31       Impact factor: 3.623

10.  Radial head prosthesis: results overview.

Authors:  E Carità; A Donadelli; L Cugola; P Perazzini
Journal:  Musculoskelet Surg       Date:  2017-08-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.