Fast microtomography using bright monochromatic x-rays.

J W Jung1, J S Lee, N Kwon, S J Park, S Chang, J Kim, J Pyo, Y Kohmura, Y Nishino, M Yamamoto, T Ishikawa, J H Je.   

Abstract

A fast microtomography system for high-resolution high-speed imaging has been developed using bright monochromatic x-rays at the BL29XU beamline of SPring-8. The shortest scan time for microtomography we attained was 0.25 s in 1.25 μm effective pixel size by combining the bright monochromatic x-rays, a fast rotating sample stage, and a high performance x-ray imaging detector. The feasibility of the tomography system was successfully demonstrated by visualization of rising bubbles in a viscous liquid, an interesting issue in multiphase flow physics. This system also provides a high spatial (a measurable feature size of 300 nm) or a very high temporal (9.8 μs) resolution in radiographs.