AIM: To present the clinical and radiological follow-up results of coil embolization using the Enterprise stent for intracranial saccular aneurysms.
MATERIALS AND METHODS: The clinical and morphological outcomes of 261 consecutive patients with a total of 289 aneurysms that were treated with a stent-protected coiling technique using the Enterprise stent from June 2008 to August 2011 were assessed.
RESULTS: Stents were delivered before first coil insertion in 162 aneurysms (56.1%), during coiling in 68 (23.5%), and after completion of coil insertion in 59 (20.4%). Procedure-related complications occurred in 36 patients (13.8%), and four (1.5%) suffered permanent neurological sequelae. Successful occlusion after coil embolization was achieved in 205 aneurysms (70.9%) and subtotal occlusion was achieved in 84. During the mean follow-up of 12.4 (±5.8) months, follow-up imaging of 229 aneurysms (79.2%) documented stable occlusion in 183 (79.9%) of the lesions, minor recanalization in 17 (7.4%), and major recanalization in 29 (12.7%). Follow-up angiography of 110 aneurysms (38.1%) demonstrated in-stent stenosis in 14 (12.7%) and stent migration in five (4.5%). Eleven patients (4.2%) suffered late delayed infarction during the follow-up period, which was related to cessation or modification of anti-platelet medication.
CONCLUSION: The stent-protection technique using the Enterprise stent is useful and effective for coil embolization of wide-necked aneurysms due to easy navigation and precise placement. However, the possibility of procedure-related complications, in-stent stenosis, and delayed cerebral infarction should be noted.
Copyright © 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23017739     DOI: 10.1016/j.crad.2012.07.017

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  19 in total

1.  Trapping of endovascular microguidewire: a rare and serious complication during therapeutic microcatheterization for cerebrovascular disease.

Authors:  Y D Cho; C H Kim; H-S Kang; M H Han; S H Kim
Journal:  Clin Neuroradiol       Date:  2014-01-03       Impact factor: 3.649

2.  Does stent-assisted coiling still have a place in the management of intracranial aneurysms?

Authors:  L Pierot; C Cognard
Journal:  AJNR Am J Neuroradiol       Date:  2013-06-06       Impact factor: 3.825

3.  Thromboelastography for monitoring platelet function in unruptured intracranial aneurysm patients undergoing stent placement.

Authors:  Hongchao Yang; Youxiang Li; Yuhua Jiang; Xianli Lv
Journal:  Interv Neuroradiol       Date:  2015-02       Impact factor: 1.610

4.  Microguidewire protection of wide-necked aneurysms incorporating orifices of tortuous acute-angled vessels: a novel approach.

Authors:  Young Dae Cho; Hyun-Seung Kang; Jeong Eun Kim; Jun Hyong Ahn; Seung Chai Jung; Chang Hun Kim; Moon Hee Han
Journal:  Neuroradiology       Date:  2014-04-23       Impact factor: 2.804

5.  Modified coil protection for proper coil frame configuration in wide-necked aneurysms.

Authors:  Young Dae Cho; Jong Kook Rhim; Jeong Jin Park; Jin Pyeong Jeon; Hyun-Seung Kang; Jeong Eun Kim; Won-Sang Cho; Moon Hee Han
Journal:  Neuroradiology       Date:  2015-03-28       Impact factor: 2.804

Review 6.  Complications in Stent-Assisted Endovascular Therapy of Ruptured Intracranial Aneurysms and Relevance to Antiplatelet Administration: A Systematic Review.

Authors:  C-W Ryu; S Park; H S Shin; J S Koh
Journal:  AJNR Am J Neuroradiol       Date:  2015-07-02       Impact factor: 3.825

7.  Does stent type impact coil embolization outcomes in extended follow-up of small-sized aneurysms (< 10 mm)?

Authors:  Jeongjun Lee; Young Dae Cho; Dong Hyun Yoo; Hyun-Seung Kang; Won-Sang Cho; Jeong Eun Kim; Jusun Moon; Moon Hee Han
Journal:  Neuroradiology       Date:  2018-04-20       Impact factor: 2.804

8.  Coil embolization in precommunicating (A1) segment aneurysms of anterior cerebral artery.

Authors:  Young Dae Cho; Jun Hyong Ahn; Seung Chai Jung; Chang Hun Kim; Hyun-Seung Kang; Jeong Eun Kim; Young Je Son; Moon Hee Han
Journal:  Neuroradiology       Date:  2014-01-26       Impact factor: 2.804

9.  Modified protection using far proximal portion of self-expandable closed-cell stents for embolization of wide-necked intracranial aneurysms.

Authors:  Young Dae Cho; Hyun-Seung Kang; Jeong Eun Kim; Won-Sang Cho; Hyon-Jo Kwon; Hyeon-Song Koh; Moon Hee Han
Journal:  Neuroradiology       Date:  2014-07-20       Impact factor: 2.804

10.  Coil embolization of intracranial saccular aneurysms using the Low-profile Visualized Intraluminal Support (LVIS™) device.

Authors:  Young Dae Cho; Chul-Ho Sohn; Hyun-Seung Kang; Jeong Eun Kim; Won-Sang Cho; Gyojun Hwang; O-Ki Kwon; Mi-Sun Ko; Nam-Mi Park; Moon Hee Han
Journal:  Neuroradiology       Date:  2014-04-17       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.