Literature DB >> 2301730

Precise relative ion abundances from Fourier transform ion cyclotron resonance magnitude-mode mass spectra.

Z M Liang1, A G Marshall.   

Abstract

The area under a correctly phased absorption-mode spectral peak is a direct measure of the number of oscillators (ions, spins, molecules) in Fourier transform spectrometry (ion cyclotron resonance, magnetic resonance, interferometry absorbance). However, phase correction can prove difficult when (as in broad-band Fourier transform ion cyclotron resonance (FT/ICR] detection is considerably time-delayed after excitation. In the absence of noise, Huang, Rempel, and Gross showed that a "complex area" method yields the correct absorption-mode peak area, for an unphased noiseless spectrum. In this paper, we show that the number of oscillators may also be obtained from a least-squares fit to a magnitude-mode (i.e., phase-independent) spectrum. In the presence of noise and in the absence of peak overlap, the magnitude-mode method offers precision superior to that based on magnitude-mode peak height, "complex area", or even direct digital integration of a correctly phased absorption-mode peak, as demonstrated by both theoretical derivation and experimental FT/ICR results. The present method thus appears to offer the best available determination of the relative abundances of ions of different mass-to-charge ratio in FT/ICR mass spectrometry.

Mesh:

Year:  1990        PMID: 2301730     DOI: 10.1021/ac00200a013

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  A glow discharge ion source with fourier transform ion cyclotron resonance mass spectrometric detection.

Authors:  C M Barhick; J R Eyler
Journal:  J Am Soc Mass Spectrom       Date:  1992-02       Impact factor: 3.109

2.  Analysis and elimination of systematic errors originating from coulomb mutual interaction and image charge in Fourier transform ion cyclotron resonance precise mass difference measurements.

Authors:  M V Gorshkov; A G Marshall; E N Nikolaev
Journal:  J Am Soc Mass Spectrom       Date:  1993-11       Impact factor: 3.109

3.  A robust error model for iTRAQ quantification reveals divergent signaling between oncogenic FLT3 mutants in acute myeloid leukemia.

Authors:  Yi Zhang; Manor Askenazi; Jingrui Jiang; C John Luckey; James D Griffin; Jarrod A Marto
Journal:  Mol Cell Proteomics       Date:  2009-12-17       Impact factor: 5.911

4.  Gas phase fullerene anions hydrogenation by methanol followed by IRMPA dehydrogenation.

Authors:  Jean-François Greisch; Bernard Leyh; Françoise Remacle; Edwin De Pauw
Journal:  J Am Soc Mass Spectrom       Date:  2009-09-30       Impact factor: 3.109

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.