Distal locking of intramedullary nails (IMNs) is a difficult part of intramedullary nailing (IMN) that could be time-consuming and expose the surgeon, the surgery personnel and the patient to a considerable amount of radiation as fluoroscopy is usually guiding the procedure. Utilization of electromagnetic fields for that purpose offers an attractive alternative. The SURESHOT™ Distal Targeting System (Smith & Nephew, Inc., Memphis, TN, USA) is a novel commercially available radiation-free aiming system that utilizes computerized electromagnetic field tracking technology for the distal locking of IMNs. In order to evaluate the efficacy of the system we conducted the present study. Nineteen patients (six females-thirteen males, mean age 39.5 years, range 17-85 years) with closed diaphyseal fracture of the femur (eight patients) or the tibia (eleven patients) were treated with IMN using the SURESHOT™ Distal Targeting System for the distal interlocking. All targeting attempts were successful at first try and followed by correct positioning of the screws. Mean time for distal locking of tibial IMNs (two screws) was 219sec (range 200-250sec). Mean time for distal locking of femoral IMNs (two screws) was 249 (range 220-330sec). In the current study the SURESHOT™ Distal Targeting System proved to be accurate, fast and easy to learn.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23010073     DOI: 10.1016/j.injury.2012.08.051

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  11 in total

1.  Radiation-free methods for navigated screw placement in slipped capital femoral epiphysis surgery.

Authors:  Bamshad Azizi Koutenaei; Javad Fotouhi; Farshid Alambeigi; Emmanuel Wilson; Ozgur Guler; Mathew Oetgen; Kevin Cleary; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-07-18       Impact factor: 2.924

Review 2.  Meta-analysis suggests that the electromagnetic technique is better than the free-hand method for the distal locking during intramedullary nailing procedures.

Authors:  Yanbin Zhu; Hengrui Chang; Yiyang Yu; Wei Chen; Song Liu; Yingze Zhang
Journal:  Int Orthop       Date:  2016-06-02       Impact factor: 3.075

3.  Fluoroscopic freehand and electromagnetic-guided targeting system for distal locking screws of humeral intramedullary nail.

Authors:  P Persiani; M Gurzi; O Moreschini; G Di Giacomo; C Villani
Journal:  Musculoskelet Surg       Date:  2016-11-22

4.  Does electromagnetic-manual guided distal locking influence rotational alignment in antegrade femoral nailing?

Authors:  Mert Ciftdemir; Sedat A Tuncel; Mert Ozcan; Cem Copuroglu; Murat Erem
Journal:  Int Orthop       Date:  2014-12-16       Impact factor: 3.075

5.  Reducing intraoperative duration and ionising radiation exposure during the insertion of distal locking screws of intramedullary nails: a small-scale study comparing the current fluoroscopic method against radiation-free, electromagnetic navigation.

Authors:  Darren Grimwood; Jane Harvey-Lloyd
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-08-25

6.  MRI-guidance in percutaneous core decompression of osteonecrosis of the femoral head.

Authors:  Pekka Kerimaa; Matti Väänänen; Risto Ojala; Pekka Hyvönen; Petri Lehenkari; Osmo Tervonen; Roberto Blanco Sequeiros
Journal:  Eur Radiol       Date:  2015-08-01       Impact factor: 5.315

7.  Electromagnetic distal targeting system does not reduce the overall operative time of the intramedullary nailing for humeral shaft fractures.

Authors:  Lawrence Camarda; Stefania Zini; Marcello Butera; Sabastin Giambartino; Ugo Mattaliano; Francesco Raso; Roberto Sciortino; Michele D'Arienzo
Journal:  J Orthop       Date:  2018-08-24

Review 8.  Safe surgical technique: intramedullary nail fixation of tibial shaft fractures.

Authors:  Boris A Zelle; Guilherme Boni
Journal:  Patient Saf Surg       Date:  2015-12-12

9.  A distal-lock electromagnetic targeting device for intramedullary nailing: Suggestions and clinical experience.

Authors:  Guido Antonini; Wilfried Stuflesser; Cornelio Crippa; Georgios Touloupakis
Journal:  Chin J Traumatol       Date:  2016-12-01

10.  Comparison of free-hand fluoroscopic guidance and electromagnetic navigation in distal locking of tibia intramedullary nails.

Authors:  Yinsheng Wang; Bing Han; Zhigang Shi; Yu Fu; Yong Ye; Juehua Jing; Jun Li
Journal:  Medicine (Baltimore)       Date:  2018-07       Impact factor: 1.889

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.