Magnetic resonance imaging of flow dynamics in the circle of Willis.

R R Edelman1, H P Mattle, G V O'Reilly, K U Wentz, C Liu, B Zhao.   

Abstract

Magnetic resonance angiography was applied to the study of blood flow dynamics in the circle of Willis in nine patients with cerebrovascular disease and two normal volunteers. In conjunction with two-dimensional or three-dimensional gradient-echo acquisitions, selective presaturation of individual vessels was used to determine the direction of blood flow and the origin of the vascular supply. Presaturation causes signal loss within the territory supplied by the presaturated artery, without affecting vessels not crossing the presaturation slab. The results were correlated with those from transcranial Doppler sonography and conventional angiography. Magnetic resonance angiography was able to demonstrate the direction of blood flow, the presence or absence of collateral blood flow, and the blood supply to the pericallosal arteries, as well as the presence of a fetal posterior circulation. Magnetic resonance angiography is a noninvasive means for imaging the blood supply of the major intracranial arteries.

Entities:  

Mesh:

Year:  1990        PMID: 2300992     DOI: 10.1161/01.str.21.1.56

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  14 in total

1.  Selective magnetic resonance angiography of the head.

Authors:  H P Mattle; K U Wentz
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Jan-Feb       Impact factor: 2.740

Review 2.  Clinical, radiological, and functional evaluation following acute stroke.

Authors:  D G Grosset
Journal:  Br J Clin Pharmacol       Date:  1992-12       Impact factor: 4.335

Review 3.  Measurement of cerebral perfusion territories using arterial spin labelling.

Authors:  Fernando F Paiva; Alberto Tannús; Afonso C Silva
Journal:  NMR Biomed       Date:  2007-11       Impact factor: 4.044

4.  Magnetic resonance angiography in moyamoya disease.

Authors:  P A Battistella; C Carollo; P A Pellegrino; S Soriani; P Scarpa
Journal:  Childs Nerv Syst       Date:  1995-06       Impact factor: 1.475

5.  Comparison of magnetic resonance angiography and conventional angiography in sickle cell disease: clinical significance and reliability.

Authors:  A Y Kandeel; R A Zimmerman; K Ohene-Frempong
Journal:  Neuroradiology       Date:  1996-07       Impact factor: 2.804

Review 6.  Varying Evidence on Deep Hypothermic Circulatory Arrest in Thoracic Aortic Aneurysm Surgery.

Authors:  Prity Gupta; Amer Harky; Saleem Jahangeer; Benjamin Adams; Mohamad Bashir
Journal:  Tex Heart Inst J       Date:  2018-04-07

7.  Function of circle of Willis.

Authors:  Zvonimir Vrselja; Hrvoje Brkic; Stefan Mrdenovic; Radivoje Radic; Goran Curic
Journal:  J Cereb Blood Flow Metab       Date:  2014-01-29       Impact factor: 6.200

Review 8.  Arterial spin labeling for the measurement of cerebral perfusion and angiography.

Authors:  Peter Jezzard; Michael A Chappell; Thomas W Okell
Journal:  J Cereb Blood Flow Metab       Date:  2017-11-23       Impact factor: 6.200

9.  Cerebral ischemia: magnetic resonance angiography and transcranial Doppler evaluation.

Authors:  P D'Aprile; F Federico; N Medicamento; C Conte; A Carella
Journal:  Ital J Neurol Sci       Date:  1994-02

10.  Intracranial magnetic resonance angiography.

Authors:  P M Ruggieri; T J Masaryk; J S Ross; M T Modic
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Jan-Feb       Impact factor: 2.740