Derivation of factors for estimating the scatter of diagnostic x-rays from walls and ceiling slabs.

C J Martin1, D G Sutton, J Magee, S McVey, J R Williams, D Peet.   

Abstract

Computed tomography (CT) scanning rooms and interventional x-ray facilities with heavy workloads may require the installation of shielding to protect against radiation scattered from walls or ceiling slabs. This is particularly important for the protection of those operating x-ray equipment from within control cubicles who may be exposed to radiation scattered from the ceiling over the top of the protective barrier and round the side if a cubicle door is not included. Data available on the magnitude of this tertiary scatter from concrete slabs are limited. Moreover, there is no way in which tertiary scatter levels can be estimated easily for specific facilities. There is a need for a suitable method for quantification of tertiary scatter because of the increases in workloads of complex x-ray facilities. In this study diagnostic x-ray air kerma levels scattered from concrete and brick walls have been measured to verify scatter factors. The results have been used in a simulation of tertiary scatter for x-ray facilities involving summation of scatter contributions from elements across concrete ceiling slabs. The majority of the ceiling scatter air kerma to which staff behind a barrier will be exposed arises from the area between the patient/x-ray tube and the staff. The level depends primarily on the heights of the ceiling and protective barrier. A method has been developed to allow tertiary scatter levels to be calculated using a simple equation based on a standard arrangement for rooms with different ceiling and barrier heights. Coefficients have been derived for a CT facility and an interventional suite to predict tertiary scatter levels from the workload, so that consideration can be given to the protection options available.

Entities:  

Mesh:

Year:  2012        PMID: 23006642     DOI: 10.1088/0952-4746/32/4/373

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  2 in total

1.  COMP Report: A survey of radiation safety regulations for medical imaging x-ray equipment in Canada.

Authors:  Thorarin A Bjarnason; Robert Rees; Judy Kainz; Lawrence H Le; Errol E Stewart; Brent Preston; Idris Elbakri; Ingvar A J Fife; Ting-Yim Lee; I Martin Benoît Gagnon; Clément Arsenault; Pierre Therrien; Edward Kendall; Elena Tonkopi; Michelle Cottreau; John E Aldrich
Journal:  J Appl Clin Med Phys       Date:  2019-09-20       Impact factor: 2.243

2.  An international survey on the clinical use of rigid and deformable image registration in radiotherapy.

Authors:  Johnson Yuen; Jeffrey Barber; Anna Ralston; Alison Gray; Amy Walker; Nicholas Hardcastle; Laurel Schmidt; Kristie Harrison; Joel Poder; Jonathan R Sykes; Michael G Jameson
Journal:  J Appl Clin Med Phys       Date:  2020-09-11       Impact factor: 2.243

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.