M Tuszewski1, A Smirnov, M C Thompson, S Korepanov, T Akhmetov, A Ivanov, R Voskoboynikov, L Schmitz, D Barnes, M W Binderbauer, R Brown, D Q Bui, R Clary, K D Conroy, B H Deng, S A Dettrick, J D Douglass, E Garate, F J Glass, H Gota, H Y Guo, D Gupta, S Gupta, J S Kinley, K Knapp, A Longman, M Hollins, X L Li, Y Luo, R Mendoza, Y Mok, A Necas, S Primavera, E Ruskov, J H Schroeder, L Sevier, A Sibley, Y Song, X Sun, E Trask, A D Van Drie, J K Walters, M D Wyman.
Abstract
Field reversed configurations (FRCs) with high confinement are obtained in the C-2 device by combining plasma gun edge biasing and neutral beam injection. The plasma gun creates an inward radial electric field that counters the usual FRC spin-up. The n = 2 rotational instability is stabilized without applying quadrupole magnetic fields. The FRCs are nearly axisymmetric, which enables fast ion confinement. The plasma gun also produces E × B shear in the FRC edge layer, which may explain the observed improved particle transport. The FRC confinement times are improved by factors 2 to 4, and the plasma lifetimes are extended from 1 to up to 4 ms.Entities:
Year: 2012 PMID: 23004613 DOI: 10.1103/PhysRevLett.108.255008