Literature DB >> 23003562

Umbilical cord presentation after use of a trans-cervical balloon catheter.

Takashi Yamada1, Soromon Kataoka, Masamitsu Takeda, Takashi Kojima, Takahiro Yamada, Mamoru Morikawa, Katsuya Tsuda, Kaoru Hanatani, Tatsumi Yamaguchi, Hisanori Minakami.   

Abstract

AIM: To examine the incidence of umbilical cord presentation, including cord prolapse (UCP) and cord descent (UCD), after the use of a trans-cervical balloon catheter (TCBC), such as a Foley catheter and a metreurynter, for the induction of labor (IOL).
METHODS: A retrospective medical chart review was conducted, focusing on the occurrence of UCP and UCD in 800 women who underwent IOL with a TCBC at five hospitals during the study period (2008-2009 for two hospitals and 2006-2009 for three hospitals). The five hospitals had a total of 8245 deliveries during the study period. UCP and UCD were defined as the descent of the umbilical cord in advance of the presenting fetal part in the presence and absence of rupture of fetal membranes, respectively.
RESULTS: The frequency of IOL using a TCBC with 70-250 mL of saline varied among the five hospitals from 4.9% to 18.8% (mean ± SD, 10.7 ± 5.0%). UCP and UCD occurred in two and four women, respectively, with the frequency of cord presentation varying among the hospitals from 0.0% to 1.8% (mean ± SD, 0.9 ± 0.9%); the cord presentation was significantly more likely to occur when 180-250 mL of saline was used, compared with when 70-150 mL of saline was used (8.2% [5/61] vs 0.15% [1/662], P < 0.0001). A change in the presenting fetal body part also occurred in 0.5% (4/800) of the women.
CONCLUSION: The use of a TCBC with 180-250 mL of saline increases the risk of cord presentation.
© 2012 The Authors. Journal of Obstetrics and Gynaecology Research © 2012 Japan Society of Obstetrics and Gynecology.

Entities:  

Mesh:

Year:  2012        PMID: 23003562     DOI: 10.1111/j.1447-0756.2012.02008.x

Source DB:  PubMed          Journal:  J Obstet Gynaecol Res        ISSN: 1341-8076            Impact factor:   1.730


  3 in total

1.  Fetal demise and associated factors following umbilical cord prolapse in Mulago hospital, Uganda: a retrospective study.

Authors:  Esau Wangi Wasswa; Sarah Nakubulwa; Twaha Mutyaba
Journal:  Reprod Health       Date:  2014-02-01       Impact factor: 3.223

2.  The use of balloons for uterine cervical ripening is associated with an increased risk of umbilical cord prolapse: population based questionnaire survey in Japan.

Authors:  Junichi Hasegawa; Akihiko Sekizawa; Tomoaki Ikeda; Mitsuhiko Koresawa; Isamu Ishiwata; Masakiyo Kawabata; Katsuyuki Kinoshita
Journal:  BMC Pregnancy Childbirth       Date:  2015-01-22       Impact factor: 3.007

3.  Hygroscopic dilators vs balloon catheter ripening of the cervix for induction of labor in nulliparous women at term: Retrospective study.

Authors:  Ryosuke Shindo; Shigeru Aoki; Naohiro Yonemoto; Yuriko Yamamoto; Junko Kasai; Michi Kasai; Etsuko Miyagi
Journal:  PLoS One       Date:  2017-12-22       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.