Literature DB >> 23001897

Analysis of procedural effects of percutaneous edge-to-edge mitral valve repair by 2D and 3D echocardiography.

Ertunc Altiok1, Sandra Hamada, Kathrin Brehmer, Kathrin Kuhr, Sebastian Reith, Michael Becker, Jörg Schröder, Mohammad Almalla, Walter Lehmacher, Nikolaus Marx, Rainer Hoffmann.   

Abstract

BACKGROUND: Analysis of procedural effects in patients undergoing percutaneous mitral valve repair (PMVR) using the edge-to-edge technique is complex, and common methods to define mitral regurgitation severity based on 2-dimensional (2D) echocardiography are not validated for postprocedural double-orifice mitral valve. This study used 3D transesophageal echocardiography (TEE) to determine the functional and morphological effects of PMVR. METHODS AND
RESULTS: In 39 high-risk surgical patients with moderate to severe functional mitral valve regurgitation, 3D TEE with and without color Doppler as well as 2D transthoracic and TEE was performed before and after PMVR (MitraClip device). Mitral valve regurgitant volume by color Doppler 3D TEE was determined as the product of vena contracta areas defined by direct planimetry and velocity time integral using continuous-wave Doppler. Regurgitant volume was reduced from 84.1±38.3 mL preintervention to 35.6±25.6 mL postintervention. Patients in whom vena contracta area could be reduced >50% had a smaller preprocedural mitral annulus area compared with patients with ≤50% reduction (11.9±3.9 versus 16.1±8.5 cm(2), respectively; P=0.036) and tended to have a smaller mitral annulus circumference (13.0±2.0 versus 14.8±4.1 cm, respectively; P=0.112). At 6 months follow-up, left atrial and left ventricular end-diastolic volumes were significantly more reduced in patients in whom regurgitant vena contracta area was reduced by >50% compared with those with less reduction (-11.4±5.2 versus -4.8±7.7%; P=0.005, and -11.0±7.2 versus -4.5±9.3%; P=0.028). The maximum diastolic mitral valve area decreased from 6.0±2.0 to 2.9±0.9 cm(2) (P<0.0001).
CONCLUSIONS: Three dimensional TEE demonstrates significant reduction of regurgitant volume after PMVR. The unique visualization of the mitral valve by 3D TEE allows improved understanding of the morphological and functional changes induced by PMVR.

Entities:  

Mesh:

Year:  2012        PMID: 23001897     DOI: 10.1161/CIRCIMAGING.112.974691

Source DB:  PubMed          Journal:  Circ Cardiovasc Imaging        ISSN: 1941-9651            Impact factor:   7.792


  20 in total

1.  Initial clinical experience using the EchoNavigator(®)-system during structural heart disease interventions.

Authors:  Jan Balzer; Tobias Zeus; Katharina Hellhammer; Verena Veulemans; Silke Eschenhagen; Eva Kehmeier; Christian Meyer; Tienush Rassaf; Malte Kelm
Journal:  World J Cardiol       Date:  2015-09-26

Review 2.  [Imaging in mitral valve interventions].

Authors:  F Kreidel; H Alessandrini; C Frerker; T Thielsen; U Schäfer; K H Kuck
Journal:  Herz       Date:  2013-08       Impact factor: 1.443

Review 3.  Incremental value of 3-D transesophageal echocardiographic imaging of the mitral valve.

Authors:  Sonia Jain; Joseph F Malouf
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

Review 4.  Three-dimensional echocardiography of the mitral valve: lessons learned.

Authors:  Francesco Maffessanti; Oana Mirea; Gloria Tamborini; Mauro Pepi
Journal:  Curr Cardiol Rep       Date:  2013-07       Impact factor: 2.931

5.  Cardiac magnetic resonance imaging in patients undergoing percutaneous mitral valve repair with the MitraClip system.

Authors:  Patrick Krumm; Christine S Zuern; Thomas H Wurster; Stefanie Mangold; Bernhard D Klumpp; Andreas Henning; Iris I Mueller; Christiane Bretschneider; Axel Bauer; Ulrich Kramer; Andreas E May
Journal:  Clin Res Cardiol       Date:  2014-01-30       Impact factor: 5.460

Review 6.  Intracardiac Echocardiography for Structural Heart and Electrophysiological Interventions.

Authors:  Craig Basman; Yuvrajsinh J Parmar; Itzhak Kronzon
Journal:  Curr Cardiol Rep       Date:  2017-09-06       Impact factor: 2.931

7.  Quantification of mitral regurgitation during percutaneous mitral valve repair: added value of simultaneous hemodynamic and 3D echocardiographic assessment.

Authors:  Ilonka Rohm; Tudor C Poerner; Ali Hamadanchi; Sylvia Otto; Torsten Doenst; Christian Jung; P Christian Schulze; Björn Goebel
Journal:  Int J Cardiovasc Imaging       Date:  2017-05-11       Impact factor: 2.357

Review 8.  [Real-time 3D echocardiography for estimation of severity in valvular heart disease : Impact on current guidelines].

Authors:  T Buck; L Bösche; B Plicht
Journal:  Herz       Date:  2017-05       Impact factor: 1.443

Review 9.  Role of Echocardiography in Transcatheter Valvular Heart Disease Interventions.

Authors:  Omar K Khalique; Rebecca T Hahn
Journal:  Curr Cardiol Rep       Date:  2017-10-27       Impact factor: 2.931

10.  Changes in dynamic mitral valve geometry during percutaneous edge-edge mitral valve repair with the MitraClip system.

Authors:  Thilo Noack; Philipp Kiefer; Linda Mallon; Philipp Lurz; Carmine Bevilacqua; Joergen Banusch; Fabian Emrich; David M Holzhey; Mani Vannan; Holger Thiele; Friedrich-Wilhelm Mohr; Michael Andrew Borger; Joerg Ender; Joerg Seeburger
Journal:  J Echocardiogr       Date:  2018-10-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.