PURPOSE: To develop a reproducible small-animal dynamic contrast-enhanced (DCE) MRI set-up for mice through which volumes <100 μL can be accurately and safely injected and to test this set-up by means of DCE measurements in resting muscle and tumor tissue. MATERIALS AND METHODS: The contrast agent (CA) injection system comprised 2 MR-compatible syringe pumps placed 50 cm from the 7T magnet bore where the fringe field is approximately 40 mT. Microbore tubing and T-connector, close to the injection site, minimized dead volume (<10 μL). For DCE-MRI measurements in 8 CB-17 SCID mice with 1500-2500 mm(3) large orthotopic neuroblastoma, a bolus of 10-fold-diluted Gd-DTPA CA solution (0.1 mmol/kg) was delivered (5 μL/s), followed by a 50-μL saline flush. Retro-orbital injections were given instead of tail vein injections, because the peripheral vasculature was reduced because of large tumor burden. RESULTS: The CA injection was successful in 19 of 24 experiments. Optical assessment showed minimal dispersion of ink-colored CA bolus. Mean (± SD) pharmacokinetic parameters retrieved from DCE-MRI examinations in resting muscle (K(trans) = 0.038 ± 0.025 min(-1), k(ep) = 0.66 ± 0.48 min(-1), v(e) = 0.060 ± 0.014, v(p) = 0.033 ± 0.021) and tumor (K(trans) = 0.082 ± 0.071 min(-1), k(ep) = 0.82 ± 0.80 min(-1), v(e) = 0.121 ± 0.075, v(p) = 0.093 ± 0.051) agreed with those reported previously. CONCLUSION: We successfully designed and implemented a DCE-MRI set-up system with short injection lines and low dead volume. The system can be used at any field strength with the syringe pumps placed at a sufficiently low fringe field (<40 mT).
PURPOSE: To develop a reproducible small-animal dynamic contrast-enhanced (DCE) MRI set-up for mice through which volumes <100 μL can be accurately and safely injected and to test this set-up by means of DCE measurements in resting muscle and tumor tissue. MATERIALS AND METHODS: The contrast agent (CA) injection system comprised 2 MR-compatible syringe pumps placed 50 cm from the 7T magnet bore where the fringe field is approximately 40 mT. Microbore tubing and T-connector, close to the injection site, minimized dead volume (<10 μL). For DCE-MRI measurements in 8 CB-17 SCIDmice with 1500-2500 mm(3) large orthotopic neuroblastoma, a bolus of 10-fold-diluted Gd-DTPA CA solution (0.1 mmol/kg) was delivered (5 μL/s), followed by a 50-μL salineflush. Retro-orbital injections were given instead of tail vein injections, because the peripheral vasculature was reduced because of large tumor burden. RESULTS: The CA injection was successful in 19 of 24 experiments. Optical assessment showed minimal dispersion of ink-colored CA bolus. Mean (± SD) pharmacokinetic parameters retrieved from DCE-MRI examinations in resting muscle (K(trans) = 0.038 ± 0.025 min(-1), k(ep) = 0.66 ± 0.48 min(-1), v(e) = 0.060 ± 0.014, v(p) = 0.033 ± 0.021) and tumor (K(trans) = 0.082 ± 0.071 min(-1), k(ep) = 0.82 ± 0.80 min(-1), v(e) = 0.121 ± 0.075, v(p) = 0.093 ± 0.051) agreed with those reported previously. CONCLUSION: We successfully designed and implemented a DCE-MRI set-up system with short injection lines and low dead volume. The system can be used at any field strength with the syringe pumps placed at a sufficiently low fringe field (<40 mT).
Authors: Thomas E Yankeelov; Laura M DeBusk; D Dean Billheimer; Jeffrey J Luci; P Charles Lin; Ronald R Price; John C Gore Journal: J Magn Reson Imaging Date: 2006-11 Impact factor: 4.813
Authors: Paxton V Dickson; John B Hamner; Christian J Streck; Catherine Y C Ng; M Beth McCarville; Christopher Calabrese; Richard J Gilbertson; Clinton F Stewart; Christy M Wilson; M Waleed Gaber; Lawrence M Pfeffer; Stephen X Skapek; Amit C Nathwani; Andrew M Davidoff Journal: Mol Cancer Res Date: 2007-06 Impact factor: 5.852
Authors: K M Donahue; R M Weisskoff; D J Parmelee; R J Callahan; R A Wilkinson; J B Mandeville; B R Rosen Journal: Magn Reson Med Date: 1995-09 Impact factor: 4.668
Authors: Paxton V Dickson; John B Hamner; Thomas L Sims; Charles H Fraga; Catherine Y C Ng; Surender Rajasekeran; Nikolaus L Hagedorn; M Beth McCarville; Clinton F Stewart; Andrew M Davidoff Journal: Clin Cancer Res Date: 2007-07-01 Impact factor: 12.531
Authors: P S Tofts; G Brix; D L Buckley; J L Evelhoch; E Henderson; M V Knopp; H B Larsson; T Y Lee; N A Mayr; G J Parker; R E Port; J Taylor; R M Weisskoff Journal: J Magn Reson Imaging Date: 1999-09 Impact factor: 4.813