Literature DB >> 22999717

A new strategy for discontinuation of dual antiplatelet therapy: the RESET Trial (REal Safety and Efficacy of 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation).

Byeong-Keuk Kim1, Myeong-Ki Hong, Dong-Ho Shin, Chung-Mo Nam, Jung-Sun Kim, Young-Guk Ko, Donghoon Choi, Tae-Soo Kang, Byoung-Eun Park, Woong-Chol Kang, Seung-Hwan Lee, Jung-Han Yoon, Bum-Kee Hong, Hyuck-Moon Kwon, Yangsoo Jang.   

Abstract

OBJECTIVES: The goal of this study was to evaluate shorter duration (3 months) dual antiplatelet therapy (DAPT) after drug-eluting stent (DES) implantation.
BACKGROUND: There have been few published reports of prospective randomized clinical studies comparing the safety and efficacy of shorter duration DAPT after DES implantation.
METHODS: We randomly assigned 2,117 patients with coronary artery stenosis into 2 groups according to DAPT duration and stent type: 3-month DAPT following Endeavor zotarolimus-eluting stent (E-ZES) implantation (E-ZES+3-month DAPT, n=1,059) versus 12-month DAPT following the other DES implantation (standard therapy, n=1,058). We hypothesized that the E-ZES+3-month DAPT would be noninferior to the standard therapy for the primary composite endpoint (cardiovascular death, myocardial infarction, stent thrombosis, target\vessel revascularization, or bleeding) at 1 year.
RESULTS: The primary endpoint occurred in 40 (4.7%) patients assigned to E-ZES+3-month DAPT compared with 41 (4.7%) patients assigned to the standard therapy (difference: 0.0%; 95% confidence interval [CI]: -2.5 to 2.5; p=0.84; p<0.001 for noninferiority). The composite rates of any death, myocardial infarction, or stent thrombosis were 0.8% and 1.3%, respectively (difference: -0.5%; 95% CI: -1.5 to 0.5; p=0.48). The rates of stent thrombosis were 0.2% and 0.3%, respectively (difference: -0.1%; 95% CI: -0.5 to 0.3; p=0.65) without its further occurrence after cessation of clopidogrel in the E-ZES+3-month DAPT group. The rates of target vessel revascularization were 3.9% and 3.7%, respectively (difference: 0.2%; 95% CI: -2.3 to 2.6; p=0.70).
CONCLUSIONS: E-ZES+3-month DAPT was noninferior to the standard therapy with respect to the occurrence of the primary endpoint. (REal Safety and Efficacy of a 3-month dual antiplatelet Therapy following E-ZES implantation [RESET]; NCT01145079).
Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22999717     DOI: 10.1016/j.jacc.2012.06.043

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  139 in total

Review 1.  Late stent thrombosis: the last remaining obstacle in coronary interventional therapy.

Authors:  Piera Capranzano; George Dangas
Journal:  Curr Cardiol Rep       Date:  2012-08       Impact factor: 2.931

2.  Optical coherence tomography analysis of the stent strut and prediction of resolved strut malapposition at 3 months after 2nd-generation drug-eluting stent implantation.

Authors:  Daisuke Izumi; Masatoshi Miyahara; Naoki Fujimoto; Shusuke Fukuoka; Masataka Sakai; Kaoru Dohi; Masaaki Ito
Journal:  Heart Vessels       Date:  2015-09-03       Impact factor: 2.037

Review 3.  The Tradeoff Between Shorter and Longer Courses of Dual Antiplatelet Therapy After Implantation of Newer Generation Drug-Eluting Stents.

Authors:  John A Bittl
Journal:  Curr Cardiol Rep       Date:  2016-01       Impact factor: 2.931

4.  Coronary intervention in 2015: Improvement of long-term outcomes after PCI.

Authors:  Uwe Zeymer
Journal:  Nat Rev Cardiol       Date:  2016-01-14       Impact factor: 32.419

5.  Comparison of the vessel healing process after everolimus-eluting stent and bare metal stent implantations in patients with ST-elevation myocardial infarction.

Authors:  Hideki Yano; Shigeo Horinaka; Manami Watahik; Tomoko Watanabe; Toshihiko Ishimitsu
Journal:  Heart Vessels       Date:  2018-11-03       Impact factor: 2.037

6.  Effect of P2Y12 Inhibitor Monotherapy vs Dual Antiplatelet Therapy on Cardiovascular Events in Patients Undergoing Percutaneous Coronary Intervention: The SMART-CHOICE Randomized Clinical Trial.

Authors:  Joo-Yong Hahn; Young Bin Song; Ju-Hyeon Oh; Woo Jung Chun; Yong Hawn Park; Woo Jin Jang; Eul-Soon Im; Jin-Ok Jeong; Byung Ryul Cho; Seok Kyu Oh; Kyeong Ho Yun; Deok-Kyu Cho; Jong-Young Lee; Young-Youp Koh; Jang-Whan Bae; Jae Woong Choi; Wang Soo Lee; Hyuck Jun Yoon; Seung Uk Lee; Jang Hyun Cho; Woong Gil Choi; Seung-Woon Rha; Joo Myung Lee; Taek Kyu Park; Jeong Hoon Yang; Jin-Ho Choi; Seung-Hyuck Choi; Sang Hoon Lee; Hyeon-Cheol Gwon
Journal:  JAMA       Date:  2019-06-25       Impact factor: 56.272

7.  Prolonged dual antiplatelet therapy after drug-eluting stenting: meta-analysis of randomized trials.

Authors:  Salvatore Cassese; Robert A Byrne; Gjin Ndrepepa; Heribert Schunkert; Massimiliano Fusaro; Adnan Kastrati
Journal:  Clin Res Cardiol       Date:  2015-04-23       Impact factor: 5.460

Review 8.  P2Y12 Inhibitor Monotherapy after Percutaneous Coronary Intervention: Is It Safe to Abandon Aspirin?

Authors:  Wen-Han Feng; I-Chang Hsieh; Yi-Heng Li
Journal:  Acta Cardiol Sin       Date:  2021-01       Impact factor: 2.672

9.  Clinical outcomes of dual antiplatelet therapy after implantation of drug-eluting stents in patients with different cardiovascular risk factors.

Authors:  Seung-Yul Lee; Myeong-Ki Hong; Dong-Ho Shin; Jung-Sun Kim; Byeong-Keuk Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Hyo-Soo Kim; Marco Valgimigli; Tullio Palmerini; Gregg W Stone
Journal:  Clin Res Cardiol       Date:  2016-09-08       Impact factor: 5.460

10.  New scoring model (DARSYM score) to predict post-discharge bleeding after successful second-generation drug-eluting stent implantation.

Authors:  Yohsuke Honda; Masahiro Yamawaki; Keisuke Hirano; Motoharu Araki; Norihiro Kobayashi; Yasunari Sakamoto; Shinsuke Mori; Masakazu Tsutumi; Takuro Takama; Takahiro Tokuda; Kenji Makino; Shigemitsu Shirai; Yoshiaki Ito
Journal:  Heart Vessels       Date:  2017-05-30       Impact factor: 2.037

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.