Literature DB >> 22999687

Long-term durability of the distal urethral polypropylene sling for the treatment of stress urinary incontinence: minimum 11-year followup.

Lisa Rogo-Gupta1, Z Chad Baxter, Ngoc-Bich Le, Shlomo Raz, Larissa V Rodríguez.   

Abstract

PURPOSE: We report on the long-term outcomes of the distal urethral polypropylene sling for stress urinary incontinence in a patient cohort that was closely followed and whose outcomes were reported at 1 and 5 years after surgery.
MATERIALS AND METHODS: We performed a prospective study of all consecutive patients who underwent a distal urethral polypropylene sling procedure between November 1999 and April 2000. The 1 and 5-year outcomes for this particular patient cohort were previously reported. At the minimum 11-year followup, outcome was determined by patient self-assessment including validated questionnaires.
RESULTS: A total of 69 patients were followed prospectively and followup was obtained for 30. Of those lost to followup 10 were deceased and 5 were cognitively impaired. Mean patient age at followup was 73 years (range 40 to 97). More than 11 years after surgery 48% of patients reported no stress urinary incontinence symptoms and 63% were never bothered by stress urinary incontinence. Patients reported a mean overall symptom improvement of 64% compared to 81% at 5 years. Overall 82% of patients met the criteria for treatment success by symptom scores and 80% met the criteria by bother scores.
CONCLUSIONS: The distal urethral polypropylene sling procedure has excellent long-term durability in the treatment of stress urinary incontinence, in addition to low morbidity and low cost as previously described. Eleven years after the procedure the majority of patients report symptom improvement. Nevertheless, many older patients are unable to participate in followup. When choosing an anti-incontinence procedure, durability should be considered in light of patient age given that the theoretical advantages of long-term durability are limited by cognitive decline and mortality.
Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22999687     DOI: 10.1016/j.juro.2012.07.033

Source DB:  PubMed          Journal:  J Urol        ISSN: 0022-5347            Impact factor:   7.450


  4 in total

1.  The Role of Obstetric Factors, miRNA-30d and miRNA-181a in Postpartum Women with Pelvic Organ Prolapse.

Authors:  Wenyu Lin; Liqing Lin; Binhua Dong; Lihua Chen; Huifang Lei; Yuqin Gao; Yaojia Chen; Pengming Sun
Journal:  Risk Manag Healthc Policy       Date:  2020-10-28

2.  Long-term durability, functional outcomes, and factors associated with surgical failure of tension-free vaginal tape procedure.

Authors:  Ji-Yeon Han; Junsoo Park; Myung-Soo Choo
Journal:  Int Urol Nephrol       Date:  2014-06-18       Impact factor: 2.370

3.  Expert Panel Recommendations on Lower Urinary Tract Health of Women Across Their Life Span.

Authors:  Liliana Losada; Cindy L Amundsen; James Ashton-Miller; Toby Chai; Clare Close; Margot Damaser; Michael DiSanto; Roger Dmochowski; Matthew O Fraser; Stephanie J Kielb; George Kuchel; Elizabeth R Mueller; Candace Parker-Autry; Alan J Wolfe; Monica P Mallampalli
Journal:  J Womens Health (Larchmt)       Date:  2016-06-10       Impact factor: 2.681

4.  Functional outcomes and quality of life after transobturatory slings: hand - made vs. commercial slings.

Authors:  Danilo Budib Lourenço; Fernando Korkes; José Eduardo Vetorazzo; Silvia da Silva Carramão; Antônio Pedro Flores Auge; Luis Gustavo Morato de Toledo
Journal:  Int Braz J Urol       Date:  2018 May-Jun       Impact factor: 1.541

  4 in total