Literature DB >> 22997766

[CHROMagar KPC. Comparison with the method proposed by the Centers for Disease Control and Prevention (CDC, USA) for rectal screening and evaluation of false positive results].

Laura Errecalde1, Sandra Cogut, Mariana Erbín, Liliana Jordá Vargas, Eugenia Cattani, Tamara Posse, Silvia Tutzer, Ricardo Hermes, Sara Kaufman.   

Abstract

Eighty one rectal swabs (RS) were cultured on CHROMagar KPC and the CDC method. Of the 81 samples, 9 were positive for KPC-producing Klebsiella pneumoniae on CHROMagar KPC, and 6 for the CDC method. CHROMagar KPC had two false positive (FP) results: 1 K. pneumoniae and 1 Acinetobacter sp. FP results on the CDC method were: 25 Acinetobacter spp., 2 Escherichia coli and 4 K. pneumoniae: CHROMagar KPC yielded a better recovery of KPC-producing bacteria and less FP results than CDC method. In order to evaluate FP results on CHROMagar KPC, 1247 RS were cultured and yielded 1021 negatives, 171 KPC-producing K. pneumoniae and 55 FP (4.4 %). Because of the FP results growing on CHROMagar KPC, KPC must be phenotypically confirmed in the bacteria isolated.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22997766