Literature DB >> 22996980

Flowmetry of left internal thoracic artery graft to left anterior descending artery: comparison between on-pump and off-pump surgery.

Filinto Marques de Cerqueira Neto1, Marco Antonio Vieira Guedes, Leonardo Eugênio Fonseca Soares, Gustavo Santiago Almeida, André Raimundo F Guimarães, Mauricio Alves Barreto, Emerson Costa Porto, Alvaro Rabelo Júnior.   

Abstract

BACKGROUND: Off-pump coronary bypass grafting (OPCAB) has become a widely used technique. Coronary flowmetry is the most common method employed to assess graft patency, nevertheless, few studies compare flow patterns between ONCAB and OPCAB surgery. The objective of this study was to compare flowmetry data in left internal mammary artery grafts bypasses to the left anterior descendent artery.
METHODS: From March to September of 2010, thirtyfive consecutive, non-randomized patients underwent CABG and were retrospectively evaluated. Ten patients were located on group A (On Pump), and twenty-five on group B (Off Pump). The mean graft flow (MGF), pulsatile index (PI) and diastolic filling (DF) were obtained using Transit Time Flowmetry (TTFM). The Fisher exact test, and Mann Whitney test were used, and a P value of < 0.05 was considered to indicate statistical significance.
RESULTS: There were no deaths, AMI, re-interventions or PTCA in a 30-day period. The number of bypasses performed per patient was 2.3 ± 0.8 in the OPCAB group, and 2.2 ± 0.6 in the ONCAB group, with no significant difference (P=0.10). The median of mean flow was 23 ml/min on group A, and 25 ml/min on group B (P=0.34). Diastolic filling percentage was 56% on group A, and 56.9% on group B (P=0.86). Pulsatile Index was 2.3 on group A, and 2.2 on group B (P=0.82).
CONCLUSIONS: There was no difference between TTFM values (MF, PI and DF) in patients operated with or without cardiopulmonary bypass.

Entities:  

Mesh:

Year:  2012        PMID: 22996980     DOI: 10.5935/1678-9741.20120045

Source DB:  PubMed          Journal:  Rev Bras Cir Cardiovasc


  4 in total

Review 1.  On-pump versus off-pump coronary artery bypass graft surgery: what do the evidence show?

Authors:  Alfredo José Rodrigues; Paulo Roberto Barbosa Evora; Paulo Victor Alves Tubino
Journal:  Rev Bras Cir Cardiovasc       Date:  2013 Oct-Dec

2.  Analysis of transit time flow of the right internal thoracic artery anastomosed to the left anterior descending artery compared to the left internal thoracic artery.

Authors:  Rodrigo Milani; Daniela de Moraes; Aline Sanches; Rodrigo Jardim; Thais Lumikoski; Gabriela Miotto; Vitor Hugo Santana; Paulo Roberto Brofman
Journal:  Rev Bras Cir Cardiovasc       Date:  2014 Apr-Jun

3.  Effects of intraoperative diltiazem infusion on flow changes in arterial and venous grafts in coronary artery bypass graft surgery.

Authors:  Ozan Erdem; Mehmet Erdem Memetoğlu; Ali İhsan Tekin; Ümit Arslan; Özgür Akkaya; Rasim Kutlu; İlhan Gölbaşı
Journal:  Rev Bras Cir Cardiovasc       Date:  2015 Jul-Aug

4.  Improving coronary artery bypass grafting: a systematic review and meta-analysis on the impact of adopting transit-time flow measurement.

Authors:  Daniel J F M Thuijs; Margreet W A Bekker; David P Taggart; A Pieter Kappetein; Teresa M Kieser; Daniel Wendt; Gabriele Di Giammarco; Gregory D Trachiotis; John D Puskas; Stuart J Head
Journal:  Eur J Cardiothorac Surg       Date:  2019-10-01       Impact factor: 4.191

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.