Literature DB >> 22996747

19F MR imaging golden angle-based capsule tracking for intestinal transit and catheter tracking: initial in vivo experience.

Tobias Hahn1, Sebastian Kozerke, Werner Schwizer, Michael Fried, Peter Boesiger, Andreas Steingoetter.   

Abstract

PURPOSE: To combine fluorine 19 ((19)F) magnetic resonance (MR) imaging and golden angle radial acquisition and to assess the feasibility of (19)F MR imaging golden angle-based tracking for catheter tracking applications and simultaneous three-dimensional (3D) intestinal tracking of ingested (19)F-labeled capsules in vivo.
MATERIALS AND METHODS: Approval from the local ethical committee and informed consent from the subject were obtained. In vitro studies were performed to assess (19)F MR imaging golden angle-based tracking reliability with regard to temporal resolution and different tracking strategies (boundary condition-free tracking, composite image-based tracking, and model-based tracking). In vivo performance of the method was investigated in one healthy volunteer on 2 days. On study day 1, a duodenal catheter incorporating five (19)F-labeled capsules was administered nasally, and its 3D movement was tracked inside the stomach and esophagus. On study day 2, three (19)F-labeled capsules were swallowed, and intestinal movement was tracked.
RESULTS: Simultaneous in vivo 3D tracking of multiple (19)F-labeled capsules was successfully performed without incorporation of boundary conditions at a temporal resolution of 252 msec. Incorporation of boundary conditions with composite image-based tracking and model-based tracking increased tracking reliability and enabled temporal resolution as high as 108 msec.
CONCLUSION: Use of (19)F MR imaging golden angle-based capsule tracking enables in vivo tracking of (19)F-labeled capsules and catheters at high temporal resolution. The presented method is applicable to physioanatomic studies of the gastrointestinal tract and shows potential for real-time tracking in interventional radiology. © RSNA, 2012.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22996747     DOI: 10.1148/radiol.12120297

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  3 in total

1.  Rapid dynamic contrast-enhanced MRI for small animals at 7T using 3D ultra-short echo time and golden-angle radial sparse parallel MRI.

Authors:  Jin Zhang; Li Feng; Ricardo Otazo; Sungheon Gene Kim
Journal:  Magn Reson Med       Date:  2018-07-29       Impact factor: 4.668

2.  Measurement of oro-caecal transit time by magnetic resonance imaging.

Authors:  Edoardo Savarino; Vincenzo Savarino; Mark Fox; Giovanni Di Leo; Manuele Furnari; Elisa Marabotto; Lorenzo Gemignani; Luca Bruzzone; Alessandro Moscatelli; Chiara De Cassan; Francesco Sardanelli; Luca Maria Sconfienza
Journal:  Eur Radiol       Date:  2015-01-11       Impact factor: 5.315

Review 3.  Magnetic resonance imaging biomarkers of gastrointestinal motor function and fluid distribution.

Authors:  Asseel Khalaf; Caroline L Hoad; Robin C Spiller; Penny A Gowland; Gordon W Moran; Luca Marciani
Journal:  World J Gastrointest Pathophysiol       Date:  2015-11-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.