Literature DB >> 22996267

Serum titanium, niobium, and aluminum levels after instrumented spinal arthrodesis in children.

Thomas P Cundy1, Georgia Antoniou, Leanne M Sutherland, Brian J C Freeman, Peter J Cundy.   

Abstract

STUDY
DESIGN: A prospective cohort study.
OBJECTIVE: To determine serum titanium, niobium, and aluminum levels in pediatric patients within the first postoperative year after instrumented spinal arthrodesis. SUMMARY OF BACKGROUND DATA: Instrumented spinal arthrodesis is a common procedure to correct scoliosis and kyphosis. Titanium-based instrumentation is increasingly favored due to enhanced biomechanical properties, but concerns have arisen regarding metal debris release and the potential for local and systemic complications.
METHODS: The pattern of systemic metal release over time was evaluated by measuring serum titanium, niobium, and aluminum levels preoperatively and 1 week, 1 month, 6 months, and 12 months after instrumented spinal arthrodesis using a titanium alloy. Serum metal levels were measured using high-resolution inductively coupled plasma mass spectrometry.
RESULTS: Thirty-two patients were included in the study group. Mean age at surgery was 14.7 years. Preoperative and postoperative concentrations of serum titanium and niobium were significantly different (P = 0.0001). Median postoperative serum concentrations of titanium and niobium were elevated 2.4- and 5.9-fold above the normal range respectively with 95% and 99% of samples elevated postoperatively. A significant and rapid rise in serum titanium and niobium levels was observed within the first postoperative week, after which elevated serum levels persisted up to 12 months.
CONCLUSION: We report abnormally elevated serum titanium and niobium levels in patients with titanium-based spinal instrumentation up to 12 months. The long-term systemic consequences of debris generated by wear and corrosion of spinal instrumentation is unclear but concerning, particularly as these implants inserted into the pediatric population may remain in situ for beyond 6 decades.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 22996267     DOI: 10.1097/BRS.0b013e3182741961

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  11 in total

1.  A randomized double-blinded clinical trial to evaluate the safety and efficacy of a novel superelastic nickel-titanium spinal rod in adolescent idiopathic scoliosis: 5-year follow-up.

Authors:  Jason Pui Yin Cheung; Dino Samartzis; Kelvin Yeung; Michael To; Keith Dip Kei Luk; Kenneth Man-Chee Cheung
Journal:  Eur Spine J       Date:  2017-08-04       Impact factor: 3.134

2.  Serum titanium, niobium and aluminium levels two years following instrumented spinal fusion in children: does implant surface area predict serum metal ion levels?

Authors:  Thomas P Cundy; William J Cundy; Georgia Antoniou; Leanne M Sutherland; Brian J C Freeman; Peter J Cundy
Journal:  Eur Spine J       Date:  2014-11       Impact factor: 3.134

3.  Letter to the Editor concerning "Spinal metallosis: a systematic review" by Goldenberg Y, Tee JW, Salinas-La Rosa CM, Murphy M (Eur Spine J; 2016, 25:1467-1473).

Authors:  Carlo Brembilla; Luigi Andrea Lanterna; Andrea Giampreti; Claudio Bernucci
Journal:  Eur Spine J       Date:  2017-06-13       Impact factor: 3.134

4.  Corrosion of Harrington rod in idiopathic scoliosis: long-term effects.

Authors:  Beth Sherman; Tanya Crowell
Journal:  Eur Spine J       Date:  2017-06-17       Impact factor: 3.134

5.  Local and systemic metal ion release occurs intraoperatively during correction and instrumented spinal fusion for scoliosis.

Authors:  William J Cundy; Annika R Mascarenhas; Georgia Antoniou; Brian J C Freeman; Peter J Cundy
Journal:  J Child Orthop       Date:  2015-01-15       Impact factor: 1.548

6.  Grafted vertebral fracture after implant removal in a patient with spine-shortening vertebral osteotomy.

Authors:  Hiroaki Nakashima; Yasutsugu Yukawa; Keigo Ito; Masaaki Machino; Shunsuke Kanbara; Daigo Morita; Shiro Imagama; Naoki Ishiguro; Fumihiko Kato
Journal:  Nagoya J Med Sci       Date:  2015-02       Impact factor: 1.131

Review 7.  A Comparison of Patient-Reported Outcome Measures Following Different Treatment Approaches for Adolescents with Severe Idiopathic Scoliosis: A Systematic Review.

Authors:  Josette Bettany-Saltikov; Hans-Rudolf Weiss; Nachiappan Chockalingam; Gokulakannan Kandasamy; Tracey Arnell
Journal:  Asian Spine J       Date:  2016-12-08

8.  Evaluation of titanium release from titanium alloy implants in patients with spinal instrumentation.

Authors:  Armağan Can Ulusaloğlu; Teoman Atici; Cenk Ermutlu; Selcan Akesen
Journal:  J Int Med Res       Date:  2021-01       Impact factor: 1.671

9.  A novel pedicle screw with mobile connection: a pilot study.

Authors:  Yasuaki Tokuhashi; Masashi Oshima; Yasumitsu Ajiro; Hiroshi Uei
Journal:  Biomed Res Int       Date:  2014-03-03       Impact factor: 3.411

10.  Evaluation of Blood Titanium Levels and Total Bone Contact Area of Dental Implants.

Authors:  Mustafa Temiz; Ertunc Dayi; Nesrin Saruhan
Journal:  Biomed Res Int       Date:  2018-06-26       Impact factor: 3.411

View more