Literature DB >> 22991920

Corrosion stability and bioactivity in simulated body fluid of silver/hydroxyapatite and silver/hydroxyapatite/lignin coatings on titanium obtained by electrophoretic deposition.

Sanja Eraković1, Ana Janković, Djordje Veljović, Eriks Palcevskis, Miodrag Mitrić, Tatjana Stevanović, Djordje Janaćković, Vesna Mišković-Stanković.   

Abstract

Hydroxyapatite is the most suitable biocompatible material for bone implant coatings. However, its brittleness is a major obstacle, and that is why, recently, research focused on creating composites with various biopolymers. In this study, hydroxyapatite coatings were modified with lignin in order to attain corrosion stability and surface porosity that enables osteogenesis. Incorporating silver, well known for its antimicrobial properties, seemed the best strategy for avoiding possible infections. The silver/hydroxyapatite (Ag/HAP) and silver/hydroxyapatite/lignin (Ag/HAP/Lig) coatings were cathaphoretically deposited on titanium from ethanol suspensions, sintered at 900 °C in Ar, and characterized by X-ray diffraction, scanning electron microscopy, field emission scanning electron microscopy, attenuated total reflection Fourier transform infrared, and X-ray photoelectron spectroscopy. The corrosion stability of electrodeposited coatings was evaluated in vitro in Kokubo's simulated body fluid (SBF) at 37 °C using electrochemical impedance spectroscopy. Bioactivity was estimated by immersion in SBF to evaluate the formation of hydroxyapatite on the coating surface. A microcrystalline structure of newly formed plate-shaped carbonate-hydroxyapatite was detected after only 7 days, indicating enhanced bioactive behavior. Both coatings had good corrosion stability during a prolonged immersion time. Among the two, the Ag/HAP/Lig coating had a homogeneous surface, less roughness, and low values of contact angle.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22991920     DOI: 10.1021/jp305252a

Source DB:  PubMed          Journal:  J Phys Chem B        ISSN: 1520-5207            Impact factor:   2.991


  9 in total

Review 1.  Calcium Phosphate Bioceramics: A Review of Their History, Structure, Properties, Coating Technologies and Biomedical Applications.

Authors:  Noam Eliaz; Noah Metoki
Journal:  Materials (Basel)       Date:  2017-03-24       Impact factor: 3.623

2.  Fabrication, characterization, and biocompatibility of ethyl cellulose/carbonated hydroxyapatite composite coatings on Ti6Al4V.

Authors:  Bo Tian; Sha Tang; Yang Li; Teng Long; Xin-Hua Qu; De-Gang Yu; Ya-Jun Guo; Ya-Ping Guo; Zhen-An Zhu
Journal:  J Mater Sci Mater Med       Date:  2014-05-24       Impact factor: 3.896

3.  Structural and biological evaluation of lignin addition to simple and silver-doped hydroxyapatite thin films synthesized by matrix-assisted pulsed laser evaporation.

Authors:  A Janković; S Eraković; C Ristoscu; N Mihailescu Serban; L Duta; A Visan; G E Stan; A C Popa; M A Husanu; C R Luculescu; V V Srdić; Dj Janaćković; V Mišković-Stanković; C Bleotu; M C Chifiriuc; I N Mihailescu
Journal:  J Mater Sci Mater Med       Date:  2015-01-13       Impact factor: 3.896

Review 4.  Lignin-Based Porous Biomaterials for Medical and Pharmaceutical Applications.

Authors:  Nan Nan; Wanhe Hu; Jingxin Wang
Journal:  Biomedicines       Date:  2022-03-23

5.  Comparative in vitro study regarding the biocompatibility of titanium-base composites infiltrated with hydroxyapatite or silicatitanate.

Authors:  Ioana-Carmen Brie; Olga Soritau; Noemi Dirzu; Cristian Berce; Adriana Vulpoi; Catalin Popa; Milica Todea; Simion Simon; Maria Perde-Schrepler; Piroska Virag; Otilia Barbos; Gabriela Chereches; Petru Berce; Valentin Cernea
Journal:  J Biol Eng       Date:  2014-06-19       Impact factor: 4.355

6.  Titanium-hydroxyapatite composites sintered at low temperature for tissue engineering: in vitro cell support and biocompatibility.

Authors:  Romina Comín; Mariana P Cid; Luciano Grinschpun; Carlos Oldani; Nancy A Salvatierra
Journal:  J Appl Biomater Funct Mater       Date:  2017-04-26       Impact factor: 2.604

7.  Functionalization of the NiTi Shape Memory Alloy Surface by HAp/SiO2/Ag Hybrid Coatings Formed on SiO2-TiO2 Glass Interlayer.

Authors:  Karolina Dudek; Mateusz Dulski; Bożena Łosiewicz
Journal:  Materials (Basel)       Date:  2020-04-02       Impact factor: 3.623

8.  Nanostructuring Effect of Nano-CeO2 Particles Reinforcing Cobalt Matrix during Electrocodeposition Process.

Authors:  Bogatu Nicoleta; Benea Lidia; Buruiană Daniela-Laura; Bașliu Vasile; Celis Jean-Pierre
Journal:  Nanomaterials (Basel)       Date:  2022-08-25       Impact factor: 5.719

9.  Novel bioactive antimicrobial lignin containing coatings on titanium obtained by electrophoretic deposition.

Authors:  Sanja Erakovic; Ana Jankovic; Gary C P Tsui; Chak-Yin Tang; Vesna Miskovic-Stankovic; Tatjana Stevanovic
Journal:  Int J Mol Sci       Date:  2014-07-11       Impact factor: 5.923

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.