Literature DB >> 22991306

Preliminary study of a novel method for conveying corrected image volumes in surgical navigation.

Amber L Simpson1, Prashanth Dumpuri, Janet E Ondrake, Jared A Weis, William R Jarnagin, Michael I Miga.   

Abstract

BACKGROUND: Commercial image-guided surgery systems rely on the fundamental assumption that preoperative medical images represent the physical state of the patient in the operating room. The guidance display typically consists of a three-dimensional (3D) model derived from medical images and three orthogonal views of the imaging data. A challenging question in image-guided surgery is: what happens when the images used in the guidance display no longer correspond to the current geometric state of the anatomy and guidance information is still desirable?
METHODS: We modify the conventional display with two techniques for incorporating a displacement field from a finite-element model into the guidance display and present a preliminary study of the effect of our method on performance with a simple surgical task. The topic of this paper is methods for conveying the computational model solution, not the model itself. To address the integration of the computational model solution into the display, a novel method of applying the deformation to the tool tip was developed, which quickly corrects for deformation but also maintains the pristine nature of the preoperative images. We compare the proposed technique to an existing method that applies the deformation field to the image volume.
RESULTS: A pilot study compared mean performance with our method of applying the deformation to the tool tip and the conventional technique. These methods were statistically similar with respect to accuracy of localization (p < 0.05) and amount of time (p < 0.05) required for localization of the target.
CONCLUSIONS: These results suggest that our new technique can be used in place of the computationally expensive task of deforming the image volume, without affecting the time or accuracy of the surgical task. Most notably, our work addresses the problem of incorporating deformation correction into the guidance display and offers a first step toward understanding its effect on surgical performance.
Copyright © 2012 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2012        PMID: 22991306      PMCID: PMC3819172          DOI: 10.1002/rcs.1459

Source DB:  PubMed          Journal:  Int J Med Robot        ISSN: 1478-5951            Impact factor:   2.547


  17 in total

1.  Evaluating statistical difference, equivalence, and indeterminacy using inferential confidence intervals: an integrated alternative method of conducting null hypothesis statistical tests.

Authors:  W W Tryon
Journal:  Psychol Methods       Date:  2001-12

2.  Modeling of retraction and resection for intraoperative updating of images.

Authors:  M I Miga; D W Roberts; F E Kennedy; L A Platenik; A Hartov; K E Lunn; K D Paulsen
Journal:  Neurosurgery       Date:  2001-07       Impact factor: 4.654

3.  Serial registration of intraoperative MR images of the brain.

Authors:  Matthieu Ferrant; Arya Nabavi; Benoît Macq; P M Black; Ferenc A Jolesz; Ron Kikinis; Simon K Warfield
Journal:  Med Image Anal       Date:  2002-12       Impact factor: 8.545

4.  Displacement estimation with co-registered ultrasound for image guided neurosurgery: a quantitative in vivo porcine study.

Authors:  Karen E Lunn; Keith D Paulsen; David W Roberts; Francis E Kennedy; Alex Hartov; John D West
Journal:  IEEE Trans Med Imaging       Date:  2003-11       Impact factor: 10.048

5.  Compensating for intraoperative soft-tissue deformations using incomplete surface data and finite elements.

Authors:  David M Cash; Michael I Miga; Tuhin K Sinha; Robert L Galloway; William C Chapman
Journal:  IEEE Trans Med Imaging       Date:  2005-11       Impact factor: 10.048

6.  Image-guided surgery of liver metastases by three-dimensional ultrasound-based optoelectronic navigation.

Authors:  S Beller; M Hünerbein; T Lange; S Eulenstein; B Gebauer; P M Schlag
Journal:  Br J Surg       Date:  2007-07       Impact factor: 6.939

7.  Model-updated image guidance: initial clinical experiences with gravity-induced brain deformation.

Authors:  M I Miga; K D Paulsen; J M Lemery; S D Eisner; A Hartov; F E Kennedy; D W Roberts
Journal:  IEEE Trans Med Imaging       Date:  1999-10       Impact factor: 10.048

Review 8.  Intraoperative magnetic resonance imaging ablation of hepatic tumors.

Authors:  Robert C G Martin
Journal:  Am J Surg       Date:  2005-04       Impact factor: 2.565

9.  Liver segmentation in living liver transplant donors: comparison of semiautomatic and manual methods.

Authors:  Laurent Hermoye; Ismael Laamari-Azjal; Zhujiang Cao; Laurence Annet; Jan Lerut; Benoit M Dawant; Bernard E Van Beers
Journal:  Radiology       Date:  2004-11-24       Impact factor: 11.105

10.  3D XFEM-based modeling of retraction for preoperative image update.

Authors:  Lara M Vigneron; Simon K Warfield; Pierre A Robe; Jacques G Verly
Journal:  Comput Aided Surg       Date:  2011
View more
  1 in total

1.  Precise Navigation of the Surgical Plane with Intraoperative Real-time Virtual Sonography and 3D Simulation in Liver Resection.

Authors:  Ang Lv; Ying Li; Hong-Gang Qian; Hui Qiu; Chun-Yi Hao
Journal:  J Gastrointest Surg       Date:  2018-07-23       Impact factor: 3.452

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.