Literature DB >> 22990385

Screw length in the guided growth method.

David Raluy-Collado1, Ignacio Sanpera, Guillem Frontera-Juan, Rafael Ramos-Asensio, Silvia Tejada-Gavela.   

Abstract

BACKGROUND: The appearance of the 8-plate as a method for hemiepiphysiodesis has renewed the interest for the use of this technique. However, many questions remain unanswered about the way of action of the guided growth method. Although screw length has been said to play no role, to our knowledge, no clinical or experimental evidence exists.
METHODS: An experimental prospective randomized study with 40 WNZ Rabbits aged 8 weeks was conducted. Four experimental groups were established. Each tibia was randomly allocated to one of the following groups: Staples (group 1), 8-plate either using self-taping screws of 9 mm (group 2), or 5 mm lengths (groups 3) and control (group 4). Radiological assessment of the tibial deformity was done in a weekly fashion, and ALDA (articular line-diaphyseal angle) variations at 6 weeks were used as the control variable.
RESULTS: The 8-plate as a whole produced a significant bigger deformity than the staples (10°). No significant differences between the two models of the 8-plate were found along the study (3.7°).
CONCLUSIONS: The 8-plate has shown to be more efficient in producing angular deformity than staples. However, the length of the screw has showed no role in the 8-plate function.

Entities:  

Mesh:

Year:  2012        PMID: 22990385     DOI: 10.1007/s00402-012-1615-3

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  3 in total

1.  Hemiepiphysiodesis for coronal angular knee deformities: tension-band plate versus percutaneous transphyseal screw.

Authors:  Galina Shapiro; Tohar Adato; Shai Paz; Tareq Shrabaty; Lamdan Ron; Naum Simanovsky; Michael Zaidman; Vladimir Goldman
Journal:  Arch Orthop Trauma Surg       Date:  2020-09-21       Impact factor: 3.067

2.  Finite element and biomechanical analysis of risk factors for implant failure during tension band plating.

Authors:  Jing Ding; Fei Wang; Fangchun Jin; Zhen-Kai Wu; Pin-Quan Shen
Journal:  J Int Med Res       Date:  2020-11       Impact factor: 1.671

Review 3.  Guided growth: mechanism and reversibility of modulation.

Authors:  Martin Gottliebsen; Juan Manuel Shiguetomi-Medina; Ole Rahbek; Bjarne Møller-Madsen
Journal:  J Child Orthop       Date:  2016-11-08       Impact factor: 1.548

  3 in total