A ring capacitor applicator in hyperthermia: energy distributions in a fat-muscle layered model for different ring electrode configurations.

G C van Rhoon1, M J Sowinski, P M van den Berg, A G Visser, H S Reinhold.   

Abstract

The energy deposition pattern within a radially layered fat-muscle phantom, diameter 135 mm, heated by a novel ring capacitor applicator has been determined experimentally as well as theoretically. Good to excellent agreement is found between measured and predicted energy distributions. For the specific absorption rate in the muscle tissue the differences are in general smaller than 6%. When the ring electrodes are placed directly on the phantom surface both measured and predicted energy distributions show the presence of superficial hot spots located within the fat layer at the site of the ring electrodes. The theoretical distributions showed that the radial component of the E-field contributes for more than 90% to the energy absorption at the hot spot in the fatty tissue in front of the ring electrodes. Introducing a small air gap (10 mm) between the phantom surface and the ring electrode results in a decrease of the energy absorption within the fatty tissue at the hot spot location by 30%. Further theoretical analysis of the energy distribution within the inhomogeneous model showed that the intensity of the hot spots at the ring electrodes can be controlled by adjustment of the applicator configuration. Independent of the size of the electrode to phantom gap the specific absorption rate values predicted in the fat-muscle model show a more favorable distribution at a frequency of 27.12 MHz than at 13.56 MHz. For a similar electrode to phantom gap the specific absorption rate within the fatty tissue is approximately two times lower at 27.12 than at 13.56 MHz. For the model calculations performed the best ratio of fat to muscle SAR (0.2) is obtained with distilled water as bolus medium in the gap.

Entities:  

Mesh:

Year:  1990        PMID: 2298638     DOI: 10.1016/0360-3016(90)90270-t

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  2 in total

1.  Radio-frequency ring applicator: energy distributions measured in the CDRH phantom.

Authors:  G C van Rhoon; P Raskmark; S N Hornsleth; P M van den Berg
Journal:  Med Biol Eng Comput       Date:  1994-11       Impact factor: 2.602

Review 2.  Present and future status of noninvasive selective deep heating using RF in hyperthermia.

Authors:  H Kato; T Ishida
Journal:  Med Biol Eng Comput       Date:  1993-07       Impact factor: 2.602

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.