Literature DB >> 22985605

Effects of exogenous oxytocin on uterine blood flow in puerperal dairy cows: the impact of days after parturition and retained fetal membranes.

Fumie Magata1, Desiree Hartmann, Mitsuo Ishii, Ryotaro Miura, Hiroto Takahashi, Motozumi Matsui, Katsuya Kida, Akio Miyamoto, Heinrich Bollwein.   

Abstract

The objective of this study was to examine whether an oxytocin challenge test (OCT), evaluated by measuring the changes in uterine blood flow using transrectal colour Doppler ultrasonography, is a suitable non-invasive method to determine uterine contractility in puerperal dairy cows. The changes in uterine blood flow during uterine contractions induced by oxytocin were evaluated on days 2 and 5 postpartum (pp). Twelve clinically healthy Holstein cows were randomly assigned into two groups: (1) oxytocin group (n=7), 50 IU oxytocin injected IM and (2) control group (n=5), 5 mL saline injected IM. Blood flow volume (BFV) and pulsatility index (PI) in the uterine arteries were determined before and after injection for 120 min on days 2 and 5 pp. BFV declined and PI increased rapidly after oxytocin injection on day 2 (P<0.05), whereas oxytocin on day 5 pp did not cause changes in blood flow parameters. The result confirmed that uterine responsiveness to oxytocin decreases with time postpartum in healthy cows. The same OCT was applied in cows with retained fetal membranes (n=6) on day 2 pp, however uterine blood flow showed no change after oxytocin injection. The results showed that an OCT on day 2 pp may be a useful method for investigating the uterine contractile response to oxytocin (reflected as the decrease of uterine blood flow) and the potential pathophysiology of uterine involution in cows.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22985605     DOI: 10.1016/j.tvjl.2012.08.010

Source DB:  PubMed          Journal:  Vet J        ISSN: 1090-0233            Impact factor:   2.688


  3 in total

1.  Limited Accuracy of Colour Doppler Ultrasound Dynamic Tissue Perfusion Measurement in Diabetic Adults.

Authors:  Felix Stoperka; Claudia Karger; Joachim Beige
Journal:  PLoS One       Date:  2016-12-29       Impact factor: 3.240

2.  Evaluation of arterial digital blood flow using Doppler ultrasonography in healthy dairy cows.

Authors:  H Müller; M Heinrich; N Mielenz; S Reese; A Steiner; A Starke
Journal:  BMC Vet Res       Date:  2017-06-06       Impact factor: 2.741

Review 3.  Cardiovascular protective properties of oxytocin against COVID-19.

Authors:  Stephani C Wang; Yu-Feng Wang
Journal:  Life Sci       Date:  2021-01-26       Impact factor: 6.780

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.