Literature DB >> 22984963

One-piece implants: placement timing, surgical technique, loading protocol, and marginal bone loss.

D R Prithviraj1, Vikas Gupta, Ninad Muley, Pushpinder Sandhu.   

Abstract

PURPOSE: Osseointegration being an accepted and well-documented concept, attention is now directed towards simplification of the mechanical design of implants and towards achieving biomechanical success. The aim of this literature review is to provide an overview of the one-piece implant, with its advantages and disadvantages over a conventional two-piece implant.
METHODS: The PubMed database was searched in the English language using the keywords one-piece implant, single-piece implant, single-stage implant surgery, and two-piece implant. Articles were selected on the basis of whether they had sufficient information related to placement timing, surgical procedure used, loading protocol, follow-up periods, marginal bone loss, and implant success rates of one-piece implants. For inclusion, a study group must have had a minimum of 30 one-piece implants followed for at least 1 year. DISCUSSION: Nineteen articles were subjected to the selection criteria. Out of 19 clinical trials only 11 met the selection criteria. Five parameters were taken into consideration for studying one-piece implants: placement timing, surgical technique, loading protocol, marginal bone loss, and implant survival rate. The data from the identified studies were tabulated according to these parameters and discussed.
CONCLUSION: Delayed placement of one-piece implants is more commonly practiced than extraction and immediate placement. Most surgeons prefer surgeries using flaps as compared to flapless surgeries, and in most cases, one-piece implants were loaded immediately. Limited literature reveals both positive and negative results regarding the effect of a one-piece implant system on surrounding hard and soft tissues.
© 2012 by the American College of Prosthodontists.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22984963     DOI: 10.1111/j.1532-849X.2012.00928.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  5 in total

1.  Minimally invasive transmucosal insertion and immediate provisonalization of one-piece implant in partially edentulous posterior mandible.

Authors:  Narpatsingh Rajput; Siyad K P; Rathinavelu G; Chandrasekaran S C; Jumshad Mohammed
Journal:  J Clin Diagn Res       Date:  2013-09-10

2.  A 3-Year Prospective Clinical Study to Evaluate the Outcome of Single-Piece Implant-Prosthetic Complex after Immediate NonFunctional Loading in the Maxillary Anterior and Mandibular Posterior Areas in Varied Bone Densities.

Authors:  Vizaikumar Vasudha Nelluri; Rajani Kumar Gedela; Kandatilparambil Maria Roseme
Journal:  Contemp Clin Dent       Date:  2022-06-21

3.  Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study.

Authors:  Ahmed Mostafa Abdelfattah Mohamed; Mohamed Gamal Askar; Mahmoud El-Moutassim Bellah El Homossany
Journal:  BMC Oral Health       Date:  2022-05-22       Impact factor: 3.747

4.  Successful mandible rehabilitation of lower incisors with one-piece implants.

Authors:  Dorina Lauritano; Roberto Grassi; Dario di Stasio; Alberta Lucchese; Massimo Petruzzi
Journal:  J Med Case Rep       Date:  2014-12-05

Review 5.  Fracture Resistance of Zirconia Oral Implants In Vitro: A Systematic Review and Meta-Analysis.

Authors:  Annalena Bethke; Stefano Pieralli; Ralf-Joachim Kohal; Felix Burkhardt; Manja von Stein-Lausnitz; Kirstin Vach; Benedikt Christopher Spies
Journal:  Materials (Basel)       Date:  2020-01-24       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.