Literature DB >> 22982530

Clinical evaluation of the incidence of prosthetic complications in implant crowns constructed with UCLA castable abutments. A cohort follow-up study.

Javier Montero1, Guillermo Manzano, David Beltrán, Christopher D Lynch, María-Jesús Suárez-García, Raquel Castillo-Oyagüe.   

Abstract

OBJECTIVES: To evaluate the incidence of prosthetic complications in implant-retained crowns made with UCLA castable abutments and to identify possible risk factors with a view to establishing recommendations to help predict the success of such restorations.
METHODS: A cohort follow-up study was carried out in 71 partially dentate patients rehabilitated with 93 implant-retained single crowns. Data regarding socio-demographic background, anatomical features, implant-, and prosthesis-related variables were recorded. The incidence rate (%), relative risk (RR) and odds ratio (OR) were applied for predictive risk factors. ANOVA and Student t-tests were used to compare quantitative variables, the chi-square test was used to compare proportions and also a logistic regression analysis was performed. The statistical significance was set at α = 0.05.
RESULTS: Two implants (2.2%) were lost during the first year of function. The incidence of prosthetic complications in the observed mean period (26.2 ± 15.4 months) was 11.9%, consisting of screw loosening (10.8%) and ceramic fracture (1.1%). A higher tendency for prosthetic complications was noticed in posterior mandibular crowns restoring saddles longer than 10 mm with mesiodistal cantilevers longer than 6mm, having natural antagonists, after long-term use (>20 months), with initial torque values superior than 30 Ncm.
CONCLUSIONS: Screw loosening is the most frequent complication in implant-retained crowns fabricated with UCLA abutments cast in cobalt-chromium. Nevertheless, the connection usually remains stable after retightening the screws. A high survival rate was recorded, and these prostheses may be a suitable treatment option. CLINICAL SIGNIFICANCE: Based on the study findings, the risk of prosthetic complications is expected to increase when long-span posterior edentulous areas are rehabilitated with single implant-supported crowns. The antagonist occlusal plane should be restored to prevent torsional forces and overloading. Implant systems with initial torque values less than 30 Ncm should be selected.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22982530     DOI: 10.1016/j.jdent.2012.09.001

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  7 in total

1.  Fracture analysis of randomized implant-supported fixed dental prostheses.

Authors:  Josephine F Esquivel-Upshaw; Alex Mehler; Arthur E Clark; Dan Neal; Kenneth J Anusavice
Journal:  J Dent       Date:  2014-07-09       Impact factor: 4.379

2.  Does matching relation exist between the length and the tilting angle of terminal implants in the all-on-four protocol? stress distributions by 3D finite element analysis.

Authors:  Xiaomei Li; Zhizhong Cao; Xiaoqian Qiu; Zhen Tang; Lulu Gong; Dalin Wang
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

3.  Stress distribution pattern of screw-retained restorations with segmented vs. non-segmented abutments: A finite element analysis.

Authors:  Shima Aalaei; Zahra Rajabi Naraki; Fatemeh Nematollahi; Elaheh Beyabanaki; Afsaneh Shahrokhi Rad
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2017-09-20

4.  Clinical Evaluation of Complications in Implant-Supported Dentures: A 4-Year Retrospective Study.

Authors:  Sabiha Zelal Ülkü; Filiz Acun Kaya; Ersin Uysal; Belgin Gulsun
Journal:  Med Sci Monit       Date:  2017-12-27

5.  Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit.

Authors:  Jorge Vélez; Jesús Peláez; Carlos López-Suárez; Rubén Agustín-Panadero; Celia Tobar; María J Suárez
Journal:  J Clin Med       Date:  2020-07-24       Impact factor: 4.241

6.  Straight and tilted implants for supporting screw-retained full-arch dental prostheses in atrophic maxillae: A 2-year prospective study.

Authors:  M Menéndez-Collar; M-A Serrera-Figallo; P Hita-Iglesias; R Castillo-Oyagüe; J-C Casar-Espinosa; A Gutiérrez-Corrales; J-L Gutiérrez-Perez; D Torres-Lagares
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2018-11-01

7.  Comparison of the maximum hand-generated torque by professors and postgraduate dental students for tightening the abutment screws of dental implants.

Authors:  Feridoun Parnia; Javad Yazdani; Parisa Fakour; Farhang Mahboub; Seyyed Mahdi Vahid Pakdel
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2018-09-18
  7 in total