The effectiveness of a single-stage versus traditional three-staged protocol of hospital disinfection at eradicating vancomycin-resistant Enterococci from frequently touched surfaces.

N Deborah Friedman1, Aaron L Walton, Sarah Boyd, Christopher Tremonti, Jillian Low, Kaylene Styles, Owen Harris, David Alfredson, Eugene Athan.   

Abstract

BACKGROUND: Environmental contamination is a reservoir for vancomycin-resistant enterococcus (VRE) in hospitals.
METHODS: Environmental sampling of surfaces was undertaken anytime before disinfection and 1 hour after disinfection utilizing a sodium dichloroisocyanurate-based, 3-staged protocol (phase 1) or benzalkonium chloride-based, single-stage clean (phase 2). VRE colonization and infection rates are presented from 2010 to 2011, and audits of cleaning completeness were also analyzed.
RESULTS: Environmental samples collected before disinfection were significantly more likely to be contaminated with VRE during phase 1 than phase 2: 25.2% versus 4.6%, respectively; odds ratio (OR), 7.01 (P < .01). Environmental samples collected after disinfection were also significantly more likely to yield VRE during phase 1 compared with phase 2: 11.2% versus 1.1%, respectively; OR, 11.73 (P < .01). Rates of VRE colonization were higher during 2010 than 2011. Cleaning audits showed similar results over both time periods.
CONCLUSION: During use of a chlorine-based, 3-staged protocol, significantly higher residual levels of VRE contamination were identified, compared with levels detected during use of a benzalkonium chloride-based product for disinfection. This reduction in VRE may be due to a new disinfection product, more attention to the thoroughness of cleaning, or other supplementary efforts in our institution.
Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22981721     DOI: 10.1016/j.ajic.2012.03.021

Source DB:  PubMed          Journal:  Am J Infect Control        ISSN: 0196-6553            Impact factor:   2.918


  4 in total

Review 1.  Best practice in healthcare environment decontamination.

Authors:  H Siani; J-Y Maillard
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2014-07-26       Impact factor: 3.267

2.  Endocarditis caused by resistant enterococcus: an overview.

Authors:  Katherine Reyes; Marcus Zervos
Journal:  Curr Infect Dis Rep       Date:  2013-08       Impact factor: 3.725

Review 3.  Cleaning Hospital Room Surfaces to Prevent Health Care-Associated Infections: A Technical Brief.

Authors:  Jennifer H Han; Nancy Sullivan; Brian F Leas; David A Pegues; Janice L Kaczmarek; Craig A Umscheid
Journal:  Ann Intern Med       Date:  2015-08-11       Impact factor: 25.391

4.  Flawed disinfectant recommendations during a pandemic.

Authors:  Trevor O Glasbey; Greg S Whiteley
Journal:  Infect Prev Pract       Date:  2020-06-15
  4 in total