Literature DB >> 22980724

Using multiple trabecular micro-bypass stents in cataract patients to treat open-angle glaucoma.

Graham W Belovay1, Abdulla Naqi, Brian J Chan, Mahmoud Rateb, Iqbal Ike K Ahmed.   

Abstract

PURPOSE: To evaluate the efficacy of multiple trabecular micro-bypass stents combined with cataract surgery in patients with open-angle glaucoma (OAG) and cataract.
SETTING: Private practice, Mississauga, Ontario, Canada.
DESIGN: Comparative case series.
METHODS: Eyes with OAG had implantation of 2 or 3 micro-bypass stents with concurrent cataract surgery and follow-up through 1 year. Efficacy measures were intraocular pressure (IOP) and topical ocular hypotensive medication use. Safety assessment included complications and corrected distance visual acuity (CDVA).
RESULTS: The study comprised 53 eyes (47 patients); 28 had implantation of 2 stents and 25 had implantation of 3 stents. The overall mean 1-year postoperative IOP was 14.3 mm Hg, which was significantly lower than preoperative IOP overall and in each group (P<.001). The target IOP was achieved in a significantly higher proportion of eyes at 1 year versus preoperatively (77% versus 43%; P<.001). Overall, 83% of eyes had a decrease in topical ocular hypotensive medication at 1 year from preoperatively, with a 74% decrease in the mean number of medications (from 2.7 to 0.7) at 1 year (P<.001). The 3-stent group was on significantly fewer medications than the 2-stent group at 1 year (0.4 versus 1.0; P=.04).
CONCLUSIONS: Using multiple micro-bypass stents with concurrent cataract surgery led to a mean postoperative IOP of less than 15 mm Hg and allowed patients to achieve target pressure control with significantly fewer medications through 1 year. FINANCIAL DISCLOSURE: Dr. Ahmed is a consultant to Glaukos Corp. No other author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22980724     DOI: 10.1016/j.jcrs.2012.07.017

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  71 in total

1.  Manchester iStent study: 3-year results and cost analysis.

Authors:  S Z Tan; L Au
Journal:  Eye (Lond)       Date:  2016-07-08       Impact factor: 3.775

2.  Ab interno canaloplasty (ABiC)-12-month results of a new minimally invasive glaucoma surgery (MIGS).

Authors:  Anja-Maria Davids; Milena Pahlitzsch; Alexander Boeker; Sibylle Winterhalter; Anna-Karina Maier-Wenzel; Matthias Klamann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-06-08       Impact factor: 3.117

3.  Implantation of trabecular micro-bypass stent using a novel "landing strip" technique.

Authors:  Cindy X Zheng; Marlene R Moster; Priyanka Gogte; Yang Dai; Remy S Manzi; Michael Waisbourd
Journal:  Int J Ophthalmol       Date:  2017-05-18       Impact factor: 1.779

Review 4.  [Possibilities for use of Scheimpflug technology in cataract surgery].

Authors:  D M Handzel; C H Meyer; A Wegener
Journal:  Ophthalmologe       Date:  2014-10       Impact factor: 1.059

5.  Cellular and cytoskeletal alterations of scleral fibroblasts in response to glucocorticoid steroids.

Authors:  Thania Bogarin; Sindhu Saraswathy; Goichi Akiyama; Xiaobin Xie; Robert N Weinreb; Jie Zheng; Alex S Huang
Journal:  Exp Eye Res       Date:  2019-08-23       Impact factor: 3.467

Review 6.  Techniques and outcomes of minimally invasive trabecular ablation and bypass surgery.

Authors:  Kevin Kaplowitz; Joel S Schuman; Nils A Loewen
Journal:  Br J Ophthalmol       Date:  2013-12-12       Impact factor: 4.638

7.  Comparison of 1-year surgical outcomes of combined cataract surgery and gonioscopy-assisted transluminal trabeculotomy (GATT) versus cataract surgery and iStent Inject.

Authors:  Hisham Hamze; Abhijit Anand Mohite; Pravin Pandey; Velota C T Sung; Imran Masood
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-05-20       Impact factor: 3.117

Review 8.  [Trabecular micro-invasive glaucoma surgery : Procedures and clinical results].

Authors:  A G M Jünemann; R Rejdak; B Hohberger
Journal:  Ophthalmologe       Date:  2018-05       Impact factor: 1.059

9.  Improvement in outflow facility by two novel microinvasive glaucoma surgery implants.

Authors:  Cassandra L Hays; Vikas Gulati; Shan Fan; Thomas W Samuelson; Iqbal Ike K Ahmed; Carol B Toris
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-03-28       Impact factor: 4.799

10.  iStent inject in phakic open angle glaucoma.

Authors:  Matthias K J Klamann; Johannes Gonnermann; Milena Pahlitzsch; Anna-Karina B Maier; Antonia M Joussen; Necip Torun; Eckart Bertelmann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-04-26       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.