Literature DB >> 22979957

Concerns regarding use of one-tailed tests in the SLED-BD vs. CVVH trial.

Gordon S Doig.   

Abstract

Entities:  

Mesh:

Year:  2012        PMID: 22979957      PMCID: PMC3682252          DOI: 10.1186/cc11490

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   9.097


× No keyword cloud information.

In the previous issue of Critical Care, I read with great interest the recent randomized controlled trial comparing sustained low-efficiency dialysis using a single-pass batch dialysis system (SLED-BD) with continuous veno-venous hemofiltration (CVVH) [1]. I congratulate the authors on their undertaking but have serious concerns regarding the majority of their analysis. After each table at the end of the paper, the authors report the use of a 'one-tailed Wilcoxon test' to assess continuous outcomes. I do not believe this use is appropriate. As the authors themselves remark, this clinical trial represents the first reasonably large trial of SLED-BD versus CVVH. Since this is the case, it is inappropriate to postulate a one-tailed hypothesis for any continuous outcomes. For example, given the available evidence, the possibility of increased intensive care unit stay or ventilator time attributable to SLED-BD cannot be excluded. Thus, a one-tailed hypothesis is not appropriate. To convert the results reported from using a one-tailed test to those using a two-tailed P value, the one-tailed P value should be doubled. For example, the P value reported in Table 3 for days of mechanical ventilation (one-tailed P = 0.047) should be adjusted to a two-tailed P value of 0.094. Similarly, all other P values obtained by using a 'one-tailed Wilcoxon test' should also be doubled.

Authors' response

Oskar Hoffmann, Vedat Schwenger, Markus A Weigand and Christian Morath Based on recently reported communications [2,3], our suggestion, at least with respect to costs, practicability, heparin consumption, and bleeding risk, was that the SLED technique is superior to CVVH. This - rather than to test whether SLED is equivalent to CVVH - was the objective of our hypothesis. In consequence of this one-sided question, we strictly used one-tailed statistical tests [1]. However, the tests used were illustrated adequately and a reader has no problem identifying the use of one-sided tests. In addition, the study was not aimed to fit the criteria for an equivalence study. Therefore, to use one-sided tests for several parameters and two-sided tests for others remains arbitrary. Nevertheless, if the reader considers this way of analysis to be inadequate, he can simply double the P values in order to support his own assessment of the results.

Abbreviations

CVVH: continuous veno-venous hemofiltration; SLED: sustained low-efficiency dialysis; SLED-BD: sustained low-efficiency dialysis using a single-pass batch dialysis system.

Competing interests

The author declares that they have no competing interests.
  3 in total

1.  Extended daily dialysis: A new approach to renal replacement for acute renal failure in the intensive care unit.

Authors:  V A Kumar; M Craig; T A Depner; J Y Yeun
Journal:  Am J Kidney Dis       Date:  2000-08       Impact factor: 8.860

2.  Efficacy and cardiovascular tolerability of extended dialysis in critically ill patients: a randomized controlled study.

Authors:  Jan T Kielstein; Ulrich Kretschmer; Thomas Ernst; Carsten Hafer; Matthias J Bahr; Hermann Haller; Danilo Fliser
Journal:  Am J Kidney Dis       Date:  2004-02       Impact factor: 8.860

3.  Sustained low efficiency dialysis using a single-pass batch system in acute kidney injury - a randomized interventional trial: the REnal Replacement Therapy Study in Intensive Care Unit PatiEnts.

Authors:  Vedat Schwenger; Markus A Weigand; Oskar Hoffmann; Ralf Dikow; Lars P Kihm; Jörg Seckinger; Nexhat Miftari; Matthias Schaier; Stefan Hofer; Caroline Haar; Peter P Nawroth; Martin Zeier; Eike Martin; Christian Morath
Journal:  Crit Care       Date:  2012-07-27       Impact factor: 9.097

  3 in total
  3 in total

Review 1.  Non-pharmacological interventions for preventing clotting of extracorporeal circuits during continuous renal replacement therapy.

Authors:  Yasushi Tsujimoto; Sho Miki; Hiroki Shimada; Hiraku Tsujimoto; Hideto Yasuda; Yuki Kataoka; Tomoko Fujii
Journal:  Cochrane Database Syst Rev       Date:  2021-09-14

2.  Sustained low-efficiency dialysis in surgical acute kidney injury - really useful?

Authors:  Matthias Heringlake; Julika Schön; Hauke Paarmann
Journal:  Crit Care       Date:  2013-01-22       Impact factor: 9.097

3.  Timing of renal replacement therapy initiation for acute kidney injury.

Authors:  Alicia Isabel I Fayad; Daniel G Buamscha; Agustín Ciapponi
Journal:  Cochrane Database Syst Rev       Date:  2018-12-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.