Literature DB >> 2297965

Extremity doses during interventional radiology.

M L Ramsdale1, W J Walker, P W Horton.   

Abstract

The radiation doses received by the unprotected parts of a radiologist undertaking biliary and renal interventional techniques using an overcouch X-ray tube have been measured with thermoluminescent dosimeters. Mean doses to the eyes, thyroid and fingers ranged from 0.27 to 1.29 mSv per examination. The results substantiate the need for such monitoring but the study demonstrates that the doses to the radiologist can be kept to an acceptable level with careful technique.

Mesh:

Year:  1990        PMID: 2297965     DOI: 10.1016/s0009-9260(05)80929-8

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  2 in total

Review 1.  Occupational radiation doses to operators performing fluoroscopically-guided procedures.

Authors:  Kwang Pyo Kim; Donald L Miller; Amy Berrington de Gonzalez; Stephen Balter; Ruth A Kleinerman; Evgenia Ostroumova; Steven L Simon; Martha S Linet
Journal:  Health Phys       Date:  2012-07       Impact factor: 1.316

2.  [Radiation burden to the hands of surgeons in intramedullary nailing].

Authors:  L P Müller; J Suffner; K Wenda; W Mohr; L Rudig
Journal:  Unfallchirurgie       Date:  1996-12
  2 in total