Literature DB >> 2297836

Two-dimensional echocardiographic determination of ventricular volumes in the fetal heart. Validation studies in fetal lambs.

K G Schmidt1, N H Silverman, G F Van Hare, J A Hawkins, J L Cloez, A M Rudolph.   

Abstract

The determination of ventricular volumes in the fetal heart from two-dimensional echocardiography (2DE) may give a better estimate of fetal ventricular size than simple diameter measurements, but the accuracy of this method has not been established. In fetal lambs, we tested whether ventricular volume calculations from 2DE using a biplane Simpson's rule algorithm are accurate. Calculations of left and right ventricular end-diastolic volumes from 2DE were compared with cast volumes of these ventricles. Also, at different levels of left atrial pressure, left ventricular stroke volumes calculated from 2DE were compared with stroke volumes measured simultaneously by an electromagnetic flowmeter. There was a good correlation between volumes determined from 2DE (y axis) and from casts (x axis) for both the left (r = 0.92; y = 0.2 + 1.1x; SEE = 0.19 ml) and right ventricle (r = 0.90; y = 0.7 + 0.9x; SEE = 0.21 ml). Left ventricular stroke volumes calculated from 2DE correlated well with those measured by the electromagnetic flowmeter (r = 0.87; y = 0.2 + 0.9x; SEE = 0.27 ml). Thus, calculation of fetal ventricular volumes from 2DE images using a biplane Simpson's rule method is feasible and accurate.

Entities:  

Mesh:

Year:  1990        PMID: 2297836     DOI: 10.1161/01.cir.81.1.325

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  5 in total

1.  Measurement of right ventricular volume in healthy term and preterm neonates.

Authors:  S J Clark; C W Yoxall; N V Subhedar
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2002-09       Impact factor: 5.747

2.  Static morphometric bases for CT identification and evaluation of the outflow chamber of the left ventricle. Preliminary study in formalin-fixed heart.

Authors:  R Demaria; G Godlewski; P De Guilhermier; J Tang; J Seguin; P A Chaptal
Journal:  Surg Radiol Anat       Date:  1993       Impact factor: 1.246

3.  Noninvasive assessment of the developing Xenopus cardiovascular system using optical coherence tomography.

Authors:  S A Boppart; G J Tearney; B E Bouma; J F Southern; M E Brezinski; J G Fujimoto
Journal:  Proc Natl Acad Sci U S A       Date:  1997-04-29       Impact factor: 11.205

4.  Determination of Fetal Left Ventricular Volume Based on Two-Dimensional Echocardiography.

Authors:  Li Yu; Yi Guo; Yuanyuan Wang; Jinhua Yu; Ping Chen
Journal:  J Healthc Eng       Date:  2017-10-23       Impact factor: 2.682

5.  Real-time 3-dimensional echocardiographic assessment of ventricular volume, mass, and function in human fetuses.

Authors:  Minjuan Zheng; Micheal Schaal; Yan Chen; Xiaokui Li; Weihui Shentu; Pengyuan Zhang; Muhammad Ashraf; Shuping Ge; David J Sahn
Journal:  PLoS One       Date:  2013-03-14       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.