Literature DB >> 22978297

Residual astigmatism following toric intraocular lens implantation related to pupil size.

Nienke Visser1, Noël J C Bauer, Rudy M M A Nuijts.   

Abstract

PURPOSE: To present two patients with residual astigmatism following toric intraocular lens (IOL) implantation.
METHODS: Case reports.
RESULTS: A 58-year-old woman underwent toric IOL implantation (spherical power 29.50 diopters [D], cylinder power 3.00 D; SN60T5, Alcon Laboratories Inc) to correct 2.33 D @ 80° of corneal astigmatism. Postoperatively, uncorrected distance visual acuity (UDVA) was 20/30 and corrected distance visual acuity (CDVA) was 20/22 (0 -1.75 × 95), indicating an overcorrection of astigmatism. Slit-lamp examination demonstrated no IOL misalignment. Wavefront aberrometry showed a large pupil diameter (>6 mm) and a lower corneal astigmatism in a 6-mm zone (-1.40 D @ 174°) compared to a 4-mm zone (-2.21 D @ 171°). The second patient, a 60-year-old man, underwent multifocal toric IOL implantation (spherical power 22.50 D, cylinder power 2.25 D; SND1T4, Alcon Laboratories Inc) to correct 1.51 D @ 173° of corneal astigmatism. Postoperatively, UDVA was 20/50 and CDVA was 20/20 (+0.25 -1.00 × 102), indicating an undercorrection of astigmatism. Slit-lamp examination showed no misalignment.
CONCLUSIONS: Both cases indicate that unexplained residual astigmatism following toric IOL implantation may be the result of multiple factors: the effect of the spherical power and anterior chamber depth on toric IOL calculations, the effect of posterior corneal astigmatism, and the effect of a large pupil size. The first two issues may be compensated for by improving toric IOL calculations. The latter indicates that pupillometry is indicated in relatively young patients who undergo toric IOL implantation. Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Year:  2012        PMID: 22978297     DOI: 10.3928/1081597X-20120911-02

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  6 in total

1.  Corrective Techniques and Future Directions for Treatment of Residual Refractive Error Following Cataract Surgery.

Authors:  Majid Moshirfar; Michael V McCaughey; Luis Santiago-Caban
Journal:  Expert Rev Ophthalmol       Date:  2014-12

2.  Comparison of the clinical outcomes of Eyecryl and Tecnis® toric intraocular lenses: A real-world study.

Authors:  Mithun Thulasidas; Ajita Sasidharan; Balam Pradeep
Journal:  Indian J Ophthalmol       Date:  2022-03       Impact factor: 2.969

3.  Comparison of the Astigmatic Power of Toric Intraocular Lenses Using Three Toric Calculators.

Authors:  Hyun Ju Park; Hun Lee; Young Jae Woo; Eung Kweon Kim; Kyoung Yul Seo; Ha Yan Kim; Tae-im Kim
Journal:  Yonsei Med J       Date:  2015-07       Impact factor: 2.759

4.  Factors Influencing Efficacy of Peripheral Corneal Relaxing Incisions during Cataract Surgery.

Authors:  Nino Hirnschall; Jörg Wiesinger; Petra Draschl; Oliver Findl
Journal:  J Ophthalmol       Date:  2015-06-25       Impact factor: 1.909

Review 5.  Surgical options for correction of refractive error following cataract surgery.

Authors:  Ahmed A Abdelghany; Jorge L Alio
Journal:  Eye Vis (Lond)       Date:  2014-10-16

6.  Comparison of the clinical efficacy of AcrySof® IQ and TECNIS® toric intraocular lenses: A real-world study.

Authors:  Juan-Juan Yang; Ya-Zhou Qin; Li Qin; Jing-Ming Li
Journal:  Exp Ther Med       Date:  2020-08-28       Impact factor: 2.447

  6 in total