Literature DB >> 22975902

Cochlear implantation assisted by noninvasive image guidance.

Nozomu Matsumoto1, Masamichi Oka, Byunghyun Cho, Jaesung Hong, Misaki Jinnouchi, Riichi Ouchida, Makoto Hashizume, Shizuo Komune.   

Abstract

OBJECTIVE: We recently developed a new noninvasive registration method for image-guided otologic surgery (STAMP method). We investigated the benefit and potential drawback of our new method in clinical application and tested the feasibility of routine image-guided surgery. STUDY
DESIGN: Retrospective case review.
SETTING: Tertiary referral university hospital. PATIENTS: Forty-six cases (45 patients) that underwent cochlear implantation in Kyushu University Hospital during the period of 2007 and 2010 were informed of the option to use navigated surgery. INTERVENTION: Twenty-five cochlear implantations were performed using STAMP-registered image-guided surgery. MAIN OUTCOME MEASURE: The error of image-guided surgery and time of surgery were collected and analyzed.
RESULTS: STAMP method offered serviceable accuracy in 18/25 cochlear implantations. The learning curve suggested that the accuracy is at least stabilizing, if not improving, and the success rate is expected to rise. Time of cochlear implant surgery was not significantly extended by the use of image guidance.
CONCLUSION: STAMP method had comparable errors with minimal invasiveness. Our new method potentially enables routine use of image-guided surgery.

Entities:  

Mesh:

Year:  2012        PMID: 22975902     DOI: 10.1097/MAO.0b013e318268d1e9

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  9 in total

1.  A preregistered STAMP method for image-guided temporal bone surgery.

Authors:  Masamichi Oka; Byunghyun Cho; Nozomu Matsumoto; Jaesung Hong; Misaki Jinnouchi; Riichi Ouchida; Shizuo Komune; Makoto Hashizume
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-06-26       Impact factor: 2.924

2.  Registration using 3D-printed rigid templates outperforms manually scanned surface matching in image-guided temporal bone surgery.

Authors:  Makoto Yamashita; Nozomu Matsumoto; Byunghyun Cho; Noritaka Komune; Shinya Onogi; Jongseung Lee; Jordan Bano; Tomohiko Akahoshi; Makoto Hashizume
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-06-14       Impact factor: 2.924

3.  Surface matching for high-accuracy registration of the lateral skull base.

Authors:  Chaozheng Zhou; Lukas Anschuetz; Stefan Weder; Le Xie; Marco Caversaccio; Stefan Weber; Tom Williamson
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-05-03       Impact factor: 2.924

4.  A clinical experience of 'STAMP' plate-guided Bonebridge implantation.

Authors:  Yutaka Takumi; Nozomu Matsumoto; Byunghyun Cho; Hidenori Ono; Kentaro Mori; Keita Tsukada; Aya Ichinose; Hidekane Yoshimura; Satoshi Iwasaki; Shizuo Komune; Shin-ichi Usami
Journal:  Acta Otolaryngol       Date:  2014-08-13       Impact factor: 1.494

5.  A cadaver study of mastoidectomy using an image-guided human-robot collaborative control system.

Authors:  Myung Hoon Yoo; Hwan Seo Lee; Chan Joo Yang; Seung Hwan Lee; Hoon Lim; Seongpung Lee; Byung-Ju Yi; Jong Woo Chung
Journal:  Laryngoscope Investig Otolaryngol       Date:  2017-09-25

6.  New frontiers and emerging applications of 3D printing in ENT surgery: a systematic review of the literature.

Authors:  P Canzi; M Magnetto; S Marconi; P Morbini; S Mauramati; F Aprile; I Avato; F Auricchio; M Benazzo
Journal:  Acta Otorhinolaryngol Ital       Date:  2018-08       Impact factor: 2.124

7.  Concept description and accuracy evaluation of a moldable surgical targeting system.

Authors:  Thomas S Rau; Sina Witte; Lea Uhlenbusch; Lüder A Kahrs; Thomas Lenarz; Omid Majdani
Journal:  J Med Imaging (Bellingham)       Date:  2021-02-19

8.  A surgical navigation system for guiding exact cochleostomy using auditory feedback: a clinical feasibility study.

Authors:  Byunghyun Cho; Nozomu Matsumoto; Shizuo Komune; Makoto Hashizume
Journal:  Biomed Res Int       Date:  2014-07-01       Impact factor: 3.411

9.  Improvements to the retractor and muscle flap design for minimally invasive cochlear implantation.

Authors:  Riyuan Liu; Zhiping Tan; Jianan Li; Yan Yan; Wei Ren; Miao Zhang; Shiming Yang; Hui Zhao
Journal:  J Otol       Date:  2019-09-24
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.