Quantification of total hexose on dry blood spot by tandem mass spectrometry.

Zhenhua Gong1, Guoli Tian, Qiwei Huang, Yanmin Wang, Qingwei Ge.   

Abstract

BACKGROUND: Because hypoglycemia and hyperglycemia are harmful and not always associated with overt clinical signs, it is necessary to have methods available to screen for glucose levels to detect hypoglycemia and diabetes as early as possible. A new method for such screening and the clinical determination of blood total hexose on a dry blood spot (DBS) using tandem mass spectrometry (MS/MS) was developed.
METHODS: The serum glucose controls and blood were prepared as DBS and then extracted into a methanol solution containing isotope-labeled internal standards. The methanolic extraction was subjected to HPLC, followed by MS/MS in positive ion mode. Multiple-reaction monitoring of m/z 203.1→23 was used to detect hexose, and m/z 209.0→23 was used for 13C6-D-glucose.
RESULTS: The recoveries of blood glucose by MS/MS were 90%-102% with an R(2) value of 0.999 after linear regression (p<0.001). The controls were within an acceptable range, and the coefficients of variation were less than 10%. The blood total hexose in neonates aged 3-7 days (6.41±1.46 mmol/L) was lower than that in neonates aged 8-30 days (6.66±1.38 mmol/L), and it was lower in neonates than in children aged 1-72 months (7.19±1.87 mmol/L).
CONCLUSION: Quantification of total hexose on a dry blood spot by MS/MS is accurate, reliable and feasible for screening and clinical tests.
Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22975641     DOI: 10.1016/j.clinbiochem.2012.08.023

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  2 in total

1.  Development and Validation of a Rapid (13)C6-Glucose Isotope Dilution UPLC-MRM Mass Spectrometry Method for Use in Determining System Accuracy and Performance of Blood Glucose Monitoring Devices.

Authors:  Risë K Matsunami; Kimon Angelides; David A Engler
Journal:  J Diabetes Sci Technol       Date:  2015-05-18

2.  Reduced glutathione and glutathione disulfide in the blood of glucose-6-phosphate dehydrogenase-deficient newborns.

Authors:  Zhen-Hua Gong; Guo-Li Tian; Qi-Wei Huang; Yan-Min Wang; Hong-Ping Xu
Journal:  BMC Pediatr       Date:  2017-07-20       Impact factor: 2.125

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.