Literature DB >> 22971722

Comparison of glucose fluctuations between day- and night-time measured using a continuous glucose monitoring system in diabetic dogs.

Akihiro Mori1, Miyuki Kurishima, Hitomi Oda, Kaori Saeki, Toshiro Arai, Toshinori Sako.   

Abstract

Monitoring of blood glucose concentration is important to evaluate the diabetic status of dogs. Continuous glucose monitoring systems (CGMS) have been applied in veterinary medicine for glucose monitoring in diabetic dogs. The purpose of the study was to evaluate the daily glycemic profiles obtained with CGMS and compare glucose fluctuations between day- and night-time in diabetic dogs. Five diabetic dogs were used in this study and were treated with either NPH insulin or insulin detemir. For data analyses, day-time was defined as 9:00 am-9:00 pm and night-time as 9:00 pm-9:00 am. Using glucose profiles, we determined the mean glucose concentrations (1- and 12-hr intervals), and times spent in hyperglycemia >200 mg/dl or hypoglycemia <60 mg/dl. None of the parameters differed significantly between day-time and night-time in dogs treated with NPH insulin or insulin detemir. In conclusion, this study confirmed, using CGMS, that there are no differences in glucose fluctuations between day- and night-time, in diabetic dogs on a similar feeding regimen and insulin administration.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22971722     DOI: 10.1292/jvms.12-0123

Source DB:  PubMed          Journal:  J Vet Med Sci        ISSN: 0916-7250            Impact factor:   1.267


  5 in total

Review 1.  Five things every community pharmacist should know when dispensing for 4-legged patients.

Authors:  Grace Frankel; Alby Kusno; Christopher Louizos
Journal:  Can Pharm J (Ott)       Date:  2016-02-05

2.  Assessment of postprandial hyperglycemia and circadian fluctuation of glucose concentrations in diabetic dogs using a flash glucose monitoring system.

Authors:  Emily K Shea; Rebecka S Hess
Journal:  J Vet Intern Med       Date:  2021-02-01       Impact factor: 3.333

3.  Clinical Use of a 180-Day Implantable Glucose Monitoring System in Dogs with Diabetes Mellitus: A Case Series.

Authors:  Antonio Maria Tardo; Concetta Irace; Francesca Del Baldo; Armando Foglia; Federico Fracassi
Journal:  Animals (Basel)       Date:  2022-03-29       Impact factor: 2.752

4.  Accuracy of a Flash Glucose Monitoring System in Diabetic Dogs.

Authors:  S Corradini; B Pilosio; F Dondi; G Linari; S Testa; F Brugnoli; P Gianella; M Pietra; F Fracassi
Journal:  J Vet Intern Med       Date:  2016-06-18       Impact factor: 3.333

5.  Comparison between a flash glucose monitoring system and a portable blood glucose meter for monitoring dogs with diabetes mellitus.

Authors:  Francesca Del Baldo; Claudia Canton; Silvia Testa; Harry Swales; Ignazio Drudi; Stefania Golinelli; Federico Fracassi
Journal:  J Vet Intern Med       Date:  2020-10-30       Impact factor: 3.333

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.