Literature DB >> 22971643

Battery-triggered microfluidic paper-based multiplex electrochemiluminescence immunodevice based on potential-resolution strategy.

Shaowei Wang1, Lei Ge, Yan Zhang, Xianrang Song, Nianqiang Li, Shenguang Ge, Jinghua Yu.   

Abstract

A potential-resolution strategy for multiplex electrochemiluminescence (ECL) immunoassay on a microfluidic paper-based analytical device (μ-PAD) was demonstrated for the first time, using tris-(bipyridine)-ruthenium(ii) (Ru(bpy)(3)(2+)) and carbon nanodots (CNDs) as the ECL labels for high-throughput ECL immunoassay on μ-PAD. Based on this strategy, simultaneous detection of four tumor markers using only two screen-printed carbon working electrodes (one electrode for two analytes) on an immunodevice consisting of a piece of patterned paper (denoted as μ-PECLI in this work) was realized, which is a simplification of the configuration of traditional μ-PADs. As a further development of μ-PECLI in low-cost and disposable applications, battery-triggered (constant-potential) ECL detection on μ-PECLI was developed, allowing the traditional electrochemical workstation to be abandoned. In addition, to exactly control the output voltage of the battery, a low-cost and simple voltage-controller was designed and fabricated for the first time. The battery-triggered ECL immunoassay principle on μ-PECLI is explained. We found that the simultaneous determination of two analytes in one paper working zone could be achieved by controlling the operational constant-potential (+1.2 V for Ru(bpy)(3)(2+) labels and -1.2 V for CNDs labels (vs. Ag/AgCl auxiliary electrode)) by simply reversing the connection mode. Finally, four tumor markers in human serum samples from the Tumor Hospital were assayed and the results obtained were in acceptable agreement with the reference values from parallel single-analyte test. This battery-triggered μ-PECLI provides a new strategy for high-throughput, low-cost, sensitive, automated and simultaneous multiplex immunoassay and point-of-care diagnosis.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22971643     DOI: 10.1039/c2lc40707h

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  9 in total

1.  High performance magnesium anode in paper-based microfluidic battery, powering on-chip fluorescence assay.

Authors:  Youngmi Koo; Jagannathan Sankar; Yeoheung Yun
Journal:  Biomicrofluidics       Date:  2014-09-05       Impact factor: 2.800

Review 2.  A review on wax printed microfluidic paper-based devices for international health.

Authors:  S Altundemir; A K Uguz; K Ulgen
Journal:  Biomicrofluidics       Date:  2017-08-30       Impact factor: 2.800

3.  High-throughput imaging assay of multiple proteins via target-induced DNA assembly and cleavage.

Authors:  Chen Zong; Jie Wu; Mengmeng Liu; Feng Yan; Huangxian Ju
Journal:  Chem Sci       Date:  2015-02-11       Impact factor: 9.825

Review 4.  Opto-Microfluidic Immunosensors: From Colorimetric to Plasmonic.

Authors:  Jie-Long He; Da-Shin Wang; Shih-Kang Fan
Journal:  Micromachines (Basel)       Date:  2016-02-15       Impact factor: 2.891

Review 5.  Fabrication, Flow Control, and Applications of Microfluidic Paper-Based Analytical Devices.

Authors:  Hosub Lim; Ali Turab Jafry; Jinkee Lee
Journal:  Molecules       Date:  2019-08-07       Impact factor: 4.411

Review 6.  Recent advances and future prospects of the potential-resolved strategy in ratiometric, multiplex, and multicolor electrochemiluminescence analysis.

Authors:  Shijun Wang; Shu Zhu; Ziqi Kang; Yidan Chen; Xiancheng Liu; Zixin Deng; Kun Hu; Guixue Wang; Yuchan Zhang; Guangchao Zang
Journal:  Theranostics       Date:  2022-09-21       Impact factor: 11.600

Review 7.  Potential Development of N-Doped Carbon Dots and Metal-Oxide Carbon Dot Composites for Chemical and Biosensing.

Authors:  Yogita Sahu; Ayesha Hashmi; Rajmani Patel; Ajaya K Singh; Md Abu Bin Hasan Susan; Sónia A C Carabineiro
Journal:  Nanomaterials (Basel)       Date:  2022-09-30       Impact factor: 5.719

Review 8.  Increasing the packing density of assays in paper-based microfluidic devices.

Authors:  Sajjad Rahmani Dabbagh; Elaina Becher; Fariba Ghaderinezhad; Hayati Havlucu; Oguzhan Ozcan; Mehmed Ozkan; Ali Kemal Yetisen; Savas Tasoglu
Journal:  Biomicrofluidics       Date:  2021-02-04       Impact factor: 2.800

9.  A solvent-free microbial-activated air cathode battery paper platform made with pencil-traced graphite electrodes.

Authors:  Seung Ho Lee; Ju Yeon Ban; Chung-Hun Oh; Hun-Kuk Park; Samjin Choi
Journal:  Sci Rep       Date:  2016-06-23       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.