Low-sample flow secondary electrospray ionization: improving vapor ionization efficiency.

G Vidal-de-Miguel1, M Macía, P Pinacho, J Blanco.   

Abstract

In secondary electrospray ionization (SESI) systems, gaseous analytes exposed to an elecrospray plume become ionized after charge is transferred from the charging electrosprayed particles to the sample species. Current SESI systems have shown a certain potential. However, their ionization efficiency is limited by space charge repulsion and by the high sample flows required to prevent vapor dilution. As a result, they have a poor conversion ratio of vapor into ions. We have developed and tested a new SESI configuration, termed low-flow SESI, that permits the reduction of the required sample flows. Although the ion to vapor concentration ratio is limited, the ionic flow to sample vapor flow ratio theoretically is not. The new ionizer is coupled to a planar differential mobility analyzer (DMA) and requires only 0.2 lpm of vapor sample flow to produce 3.5 lpm of ionic flow. The achieved ionization efficiency is 1/700 (one ion for every 700 molecules) for TNT and, thus, compared with previous SESI ionizers coupled with atmospheric pressure ionization-mass spectrometry (API-MS) (Mesonero, E.; Sillero, J. A.; Hernández, M.; Fernandez de la Mora, J. Philadelphia PA, 2009) has been improved by a large factor of at least 50-100 (our measurements indicate 70). The new ionizer coupled with the planar DMA and a triple quadrupole mass spectrometer (ABSciex API5000) requires only 20 fg (50 million molecules) to produce a discernible signal after mobility and MS(2) analysis.

Entities:  

Year:  2012        PMID: 22970991     DOI: 10.1021/ac3005378

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Exploiting the native inspiratory ability of a mass spectrometer to improve analysis efficiency.

Authors:  Qian Zhang; Lin Lin; Quan Yu; Xiaohao Wang
Journal:  RSC Adv       Date:  2020-01-24       Impact factor: 4.036

2.  Mobility Peak Tailing Reduction in a Differential Mobility Analyzer (DMA) Coupled with a Mass Spectrometer and Several Ionization Sources.

Authors:  Mario Amo-Gonzalez; Juan Fernandez de la Mora
Journal:  J Am Soc Mass Spectrom       Date:  2017-05-30       Impact factor: 3.109

3.  LED pumped polymer laser sensor for explosives.

Authors:  Yue Wang; Paulina O Morawska; Alexander L Kanibolotsky; Peter J Skabara; Graham A Turnbull; Ifor D W Samuel
Journal:  Laser Photon Rev       Date:  2013-10-08       Impact factor: 13.138

4.  Fingerprinting breast cancer vs. normal mammary cells by mass spectrometric analysis of volatiles.

Authors:  Jingjing He; Pablo Martinez-Lozano Sinues; Maija Hollmén; Xue Li; Michael Detmar; Renato Zenobi
Journal:  Sci Rep       Date:  2014-06-06       Impact factor: 4.379

5.  Isomer-Resolved Mobility-Mass Analysis of α-Pinene Ozonolysis Products.

Authors:  Aurora Skyttä; Jian Gao; Runlong Cai; Mikael Ehn; Lauri R Ahonen; Theo Kurten; Zhibin Wang; Matti P Rissanen; Juha Kangasluoma
Journal:  J Phys Chem A       Date:  2022-07-21       Impact factor: 2.944

6.  Optimizing Secondary Electrospray Ionization High-Resolution Mass Spectrometry (SESI-HRMS) for the Analysis of Volatile Fatty Acids from Gut Microbiome.

Authors:  Jisun H J Lee; Jiangjiang Zhu
Journal:  Metabolites       Date:  2020-08-28
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.