Literature DB >> 22969840

Comparative study of multi-slice CT angiography with digital subtraction angiography in the blood supply of meningiomas.

Xiangjun Han1, Yuefu Zhan, Jianqiang Chen.   

Abstract

Evaluation of multi-slice CT angiography (MSCTA) and digital subtraction angiography (DSA) was made through the comparison of the two methods in detecting the blood supply of meningiomas, providing further clues for the improved application of MSCTA and DSA in the blood supply of meningiomas. In this study, 20 patients with meningiomas underwent CT angiography by 16-slice spiral CT and inspection 1 week later using DSA. The blood supply of the meningiomas (including the tumor feeding arteries, draining veins, venous sinuses, vessels around the tumor and skull-shaped images, such as comparative evaluation) was compared. The results showed that MSCTA and DSA inspection clearly depicted tumor feeding arteries, draining veins and venous sinuses in all 20 patients. DSA was slightly more effective than MSCTA in displaying fine branches, and DSA had obvious advantages over MSCTA in displaying vessels near the skull. In the display of the tumor's compression and pushing over its peripheral vasculature, MSCTA had the three-dimensional advantage, although in displaying parasagittal sinus meningiomas, it may overestimate the presence of venous sinus invasion due to the impact of bone structure. This does not affect DSA. MSCTA accurately assesses the relationship between the tumor and the bone, and provides three-dimensional images for the pre-operative simulation of surgical approaches. Taken together, MSCTA and DSA are both able to provide important information, such as accurate visualization of tumor-feeding arteries, draining veins and venous sinuses, with high consistency. MSCTA is more advantageous in the depiction of three-dimensional relationships between the tumor and peripheral vessels and skull. Compared to DSA, MSCTA is non-invasive, faster and less costly.

Entities:  

Year:  2011        PMID: 22969840      PMCID: PMC3438678          DOI: 10.3892/etm.2011.354

Source DB:  PubMed          Journal:  Exp Ther Med        ISSN: 1792-0981            Impact factor:   2.447


  4 in total

1.  Cerebral veins: comparative study of CT venography with intraarterial digital subtraction angiography.

Authors:  S G Wetzel; E Kirsch; K W Stock; M Kolbe; A Kaim; E W Radue
Journal:  AJNR Am J Neuroradiol       Date:  1999-02       Impact factor: 3.825

Review 2.  New techniques in CT angiography.

Authors:  Michael M Lell; Katharina Anders; Michael Uder; Ernst Klotz; Hendrik Ditt; Fernando Vega-Higuera; Tobias Boskamp; Werner A Bautz; Bernd F Tomandl
Journal:  Radiographics       Date:  2006-10       Impact factor: 5.333

3.  Preoperative embolization of intracranial meningiomas.

Authors:  C Manelfe; P Lasjaunias; J Ruscalleda
Journal:  AJNR Am J Neuroradiol       Date:  1986 Sep-Oct       Impact factor: 3.825

4.  Clinical evaluation of bone-subtraction CT angiography (BSCTA) in head and neck imaging.

Authors:  M Lell; K Anders; E Klotz; H Ditt; W Bautz; B F Tomandl
Journal:  Eur Radiol       Date:  2005-11-03       Impact factor: 5.315

  4 in total
  3 in total

1.  Subtraction CT angiography for the detection of intracranial aneurysms: A meta-analysis.

Authors:  Tian-Ying Feng; Xue-Feng Han; Rui Lang; Fei Wang; Qiong Wu
Journal:  Exp Ther Med       Date:  2016-03-15       Impact factor: 2.447

2.  Diagnostic value of four-dimensional CT angiography in arterial erectile dysfunction using 320-detector row dynamic volume CT.

Authors:  Cheng-Cheng Xu; Xin-Zhong Ruan; Yi-Fan Tang; Jiao-Hai Pan; Guo-Yao Wang; Qiu-Li Huang
Journal:  Biosci Rep       Date:  2017-08-21       Impact factor: 3.840

3.  Diagnostic value of multislice computerized tomography angiography for aortic dissection: A comparison with DSA.

Authors:  Dong Lu; Cheng-Li Li; Wei-Fu Lv; Ming Ni; Ke-Xue Deng; Chun-Ze Zhou; Jing-Kun Xiao; Zhen-Feng Zhang; Xing-Ming Zhang
Journal:  Exp Ther Med       Date:  2016-12-19       Impact factor: 2.447

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.