Literature DB >> 22968138

LV wall segmentation using the variational level set method (LSM) with additional shape constraint for oedema quantification.

K Kadir1, H Gao, A Payne, J Soraghan, C Berry.   

Abstract

In this paper an automatic algorithm for the left ventricle (LV) wall segmentation and oedema quantification from T2-weighted cardiac magnetic resonance (CMR) images is presented. The extent of myocardial oedema delineates the ischaemic area-at-risk (AAR) after myocardial infarction (MI). Since AAR can be used to estimate the amount of salvageable myocardial post-MI, oedema imaging has potential clinical utility in the management of acute MI patients. This paper presents a new scheme based on the variational level set method (LSM) with additional shape constraint for the segmentation of T2-weighted CMR image. In our approach, shape information of the myocardial wall is utilized to introduce a shape feature of the myocardial wall into the variational level set formulation. The performance of the method is tested using real CMR images (12 patients) and the results of the automatic system are compared to manual segmentation. The mean perpendicular distances between the automatic and manual LV wall boundaries are in the range of 1-2 mm. Bland-Altman analysis on LV wall area indicates there is no consistent bias as a function of LV wall area, with a mean bias of -121 mm(2) between individual investigator one (IV1) and LSM, and -122 mm(2) between individual investigator two (IV2) and LSM when compared to two investigators. Furthermore, the oedema quantification demonstrates good correlation when compared to an expert with an average error of 9.3% for 69 slices of short axis CMR image from 12 patients.

Entities:  

Mesh:

Year:  2012        PMID: 22968138     DOI: 10.1088/0031-9155/57/19/6007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

1.  Automatic localization of the left ventricular blood pool centroid in short axis cardiac cine MR images.

Authors:  Li Kuo Tan; Yih Miin Liew; Einly Lim; Yang Faridah Abdul Aziz; Kok Han Chee; Robert A McLaughlin
Journal:  Med Biol Eng Comput       Date:  2017-11-17       Impact factor: 2.602

2.  Highly automatic quantification of myocardial oedema in patients with acute myocardial infarction using bright blood T2-weighted CMR.

Authors:  Hao Gao; Kushsairy Kadir; Alexander R Payne; John Soraghan; Colin Berry
Journal:  J Cardiovasc Magn Reson       Date:  2013-03-30       Impact factor: 5.364

  2 in total