Literature DB >> 22967535

Greatly extended storage stability of electrochemical DNA biosensors using ternary thiolated self-assembled monolayers.

Filiz Kuralay1, Susana Campuzano, Joseph Wang.   

Abstract

While high storage stability of sequence-selective DNA biosensors is crucial towards their routine applications, commonly used electrochemical hybridization biosensors are characterized with limited storage stability. In this article we demonstrate that recently developed ternary thiolated monolayers impart dramatic improvement in the storage stability of DNA electrochemical biosensors. In particular, highly stable multicomponent interfaces are prepared by co-immobilizing the thiolated capture probe (SHCP) with 1,6-hexanedithiol (HDT) on gold substrates, followed by the incorporation of 6-mercapto-1-hexanol (MCH) diluent. The resulting (SHCP/HDT+MCH) DNA hybridization recognition platform offers substantially higher storage stability compared to conventional binary (SHCP+MCH) monolayers. The (SHCP/HDT+MCH) ternary monolayers maintain their initial signal (S)-to-noise (N) ratio (S/N) over a prolonged 3 months period upon storage at 4 °C, compared to the rapid sensitivity loss observed using the common binary interfaces. This attractive stability performance promises the convenient usage of pre-prepared electrodes after prolonged time storage without any treatment. Such dramatic improvements in the storage stability have been achieved through a rational optimization of the concentration ratio of the SHCP and the other components of the ternary SAM. The improved storage stability of SHCP/HDT+MCH interfaces observed at higher concentrations of SHCP is attributed to a hindered displacement of SHCP by MCH in the resulting compact layers. The ability to design highly stable nucleic acid interfaces using common chemicals obviates the need of using specialized expensive reagents.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22967535     DOI: 10.1016/j.talanta.2012.05.033

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

Review 1.  Exploring the Trans-Cleavage Activity of CRISPR-Cas12a (cpf1) for the Development of a Universal Electrochemical Biosensor.

Authors:  Yifan Dai; Rodrigo A Somoza; Liu Wang; Jean F Welter; Yan Li; Arnold I Caplan; Chung Chiun Liu
Journal:  Angew Chem Int Ed Engl       Date:  2019-10-17       Impact factor: 15.336

2.  Protein analysis by time-resolved measurements with an electro-switchable DNA chip.

Authors:  Andreas Langer; Paul A Hampel; Wolfgang Kaiser; Jelena Knezevic; Thomas Welte; Valentina Villa; Makiko Maruyama; Matej Svejda; Simone Jähner; Frank Fischer; Ralf Strasser; Ulrich Rant
Journal:  Nat Commun       Date:  2013       Impact factor: 14.919

3.  Optimisation and Characterisation of Anti-Fouling Ternary SAM Layers for Impedance-Based Aptasensors.

Authors:  Anna Miodek; Edward M Regan; Nikhil Bhalla; Neal A E Hopkins; Sarah A Goodchild; Pedro Estrela
Journal:  Sensors (Basel)       Date:  2015-09-29       Impact factor: 3.576

4.  The challenge of long-term stability for nucleic acid-based electrochemical sensors.

Authors:  Alexander Shaver; Netzahualcóyotl Arroyo-Currás
Journal:  Curr Opin Electrochem       Date:  2021-12-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.