Literature DB >> 2296671

Fallopian tubes: improved technique for catheterization.

A S Thurmond1, J Rösch.   

Abstract

Successful fallopian tube catheterization for diagnosis or treatment of infertility combines hysterosalpingographic and angiographic techniques. An improvement in the catheterization strategy was developed so that angled, tortuous, or more distally obstructed fallopian tubes could be catheterized. In 22 patients, 38 fallopian tubes were catheterized by using this strategy. In nine tubes (24%), forceful ostial injection alone of contrast material was able to open and/or depict the fallopian tube. In 13 tubes (34%), a discrete obstruction was recanalized by using the standard fallopian tube catheterization set. In 12 tubes (32%), successful recanalization required the use of a softer, tapered guide wire and catheter. In four tubes (10%), recanalization was unsuccessful.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2296671     DOI: 10.1148/radiology.174.2.2296671

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  3 in total

1.  Fluoroscopic Guided Fallopian Tube Recanalisation.

Authors:  S Bhargava; Punita Arora; S Mohan
Journal:  Med J Armed Forces India       Date:  2011-05-30

Review 2.  Fallopian tube catheterization.

Authors:  Amy Suzanne Thurmond
Journal:  Semin Intervent Radiol       Date:  2013-12       Impact factor: 1.513

3.  Fallopian tube catheterization.

Authors:  Amy Suzanne Thurmond
Journal:  Semin Intervent Radiol       Date:  2008-12       Impact factor: 1.513