Literature DB >> 2296663

Dual-energy radiographic absorptiometry of the lumbar spine: clinical experience with two different systems.

C R Gundry1, C W Miller, E Ramos, A Moscona, J A Stein, R B Mazess, D J Sartoris, D Resnick.   

Abstract

Dual-energy radiographic absorptiometry (DRA) of the lumbar spine was performed in 222 subjects (aged 17-92 years) of both sexes with use of two different systems. In a sub-group of 21 patients, results were compared with those obtained by means of dual-photon absorptiometry (DPA) of the lumbar spine. There was a high correlation among the results obtained with three instruments (r = .9, P less than .0001), and interconversion factors were calculated. Data conversion based on these regression equations may be useful for comparing results from one laboratory to another.

Entities:  

Mesh:

Year:  1990        PMID: 2296663     DOI: 10.1148/radiology.174.2.2296663

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  8 in total

1.  Measurements of bone mineral density of the proximal femur by two commercially available dual energy X-ray absorptiometric systems.

Authors:  O L Svendsen; U Marslew; C Hassager; C Christiansen
Journal:  Eur J Nucl Med       Date:  1992

2.  An evaluation of dual-energy X-ray absorptiometry and comparison with dual-photon absorptiometry.

Authors:  B Lees; J C Stevenson
Journal:  Osteoporos Int       Date:  1992-05       Impact factor: 4.507

3.  A comparison of two dual-energy X-ray absorptiometry systems for spinal bone mineral measurement.

Authors:  K C Lai; M M Goodsitt; R Murano; C H Chesnut
Journal:  Calcif Tissue Int       Date:  1992-03       Impact factor: 4.333

4.  The effects of standardization and reference values on patient classification for spine and femur dual-energy X-ray absorptiometry.

Authors:  A Simmons; D E Simpson; M J O'Doherty; S Barrington; A J Coakley
Journal:  Osteoporos Int       Date:  1997       Impact factor: 4.507

5.  The effect of intranasal salmon calcitonin on postmenopausal bone turnover as assessed by biochemical markers: evidence of maximal effect after 8 weeks of continuous treatment.

Authors:  M E Kraenzlin; M J Seibel; U Trechsel; V Boerlin; M Azria; C A Kraenzlin; H G Haas
Journal:  Calcif Tissue Int       Date:  1996-04       Impact factor: 4.333

6.  Quality assurance for bone densitometry research studies: concept and impact.

Authors:  C C Glüer; K G Faulkner; M J Estilo; K Engelke; J Rosin; H K Genant
Journal:  Osteoporos Int       Date:  1993-09       Impact factor: 4.507

7.  Comparison of dual photon and dual energy X-ray bone densitometers in a clinic setting.

Authors:  D A Nelson; E B Brown; M J Flynn; D D Cody; S Shaffer
Journal:  Skeletal Radiol       Date:  1991       Impact factor: 2.199

Review 8.  Dual-Energy Computed Tomography of the Liver: Uses in Clinical Practices and Applications.

Authors:  Masakatsu Tsurusaki; Keitaro Sofue; Masatoshi Hori; Kosuke Sasaki; Kazunari Ishii; Takamichi Murakami; Masatoshi Kudo
Journal:  Diagnostics (Basel)       Date:  2021-01-22
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.