Literature DB >> 22965983

Long-term clinical and echocardiographic follow-up of the Freestyle stentless aortic bioprosthesis.

Siamak Mohammadi1, Vincent Tchana-Sato, Dimitri Kalavrouziotis, Pierre Voisine, Daniel Doyle, Richard Baillot, Sandro Sponga, Jacques Metras, Jean Perron, François Dagenais.   

Abstract

BACKGROUND: Stentless aortic bioprostheses were designed to provide enhanced hemodynamic performance and potentially greater longevity. The present report describes the outcomes of patients with the Freestyle stentless bioprosthesis followed for ≤18 years. METHODS AND
RESULTS: Between 1993 and 2011, 430 patients underwent primary aortic valve replacement with a Freestyle bioprosthesis in the subcoronary position. Mean age was 68.2 ± 8.2 years. All of the clinical and echocardiographic data were collected prospectively. Mean overall follow-up was 9.1 ± 4.4 years and was complete in all of the patients. In-hospital mortality was 3.5% (n=15). Overall, 10- and 15-year survival were 60.7% and 35.0%, respectively. Fifty-one patients required reoperation during follow-up, including 27 for structural valve deterioration (SVD). Overall, freedom from reoperation was 91.0% and 75.0% at 10 and 15 years, whereas freedom from reoperation for SVD was 95.9% and 82.3%, respectively. At 10 and 15 years, freedom from reoperation for SVD was 94.0% and 62.6% for patients <60 years of age and 96.3% and 88.4% for patients ≥60 years of age (P=0.002). The median time to explant for SVD was 10.7 years. SVD presented mostly as acute, severe aortic insufficiency attributed to leaflet tear (77.8%). The independent risk factors for reoperation for SVD were age <60 years (P=0.001) and dyslipidemia (P=0.02).
CONCLUSIONS: Aortic valve replacement with the Freestyle bioprosthesis in a subcoronary position provides good long-term clinical and echocardiographic outcomes for patients >60 years of age. Severe aortic insufficiency with leaflet tear is the major mode of SVD leading to reoperation in these patients.

Entities:  

Mesh:

Year:  2012        PMID: 22965983     DOI: 10.1161/CIRCULATIONAHA.111.084806

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  11 in total

1.  Influence of Age on Longevity of a Stentless Aortic Valve.

Authors:  Bo Yang; Aroosa Malik; Linda Farhat; Alexander Makkinejad; Elizabeth L Norton; Mohamed-Ali Sareini; Emma St Pierre; Xiaoting Wu; Jonathan Haft; Matthew Romano; Steven F Bolling; Himanshu J Patel; G Michael Deeb
Journal:  Ann Thorac Surg       Date:  2019-12-23       Impact factor: 4.330

Review 2.  Durability of prostheses for transcatheter aortic valve implantation.

Authors:  Mani Arsalan; Thomas Walther
Journal:  Nat Rev Cardiol       Date:  2016-04-07       Impact factor: 32.419

Review 3.  Biological aortic valve replacement: advantages and optimal indications of stentless compared to stented valve substitutes. A review.

Authors:  Reza Tavakoli; Pichoy Danial; Ahmed Hamid Oudjana; Peiman Jamshidi; Max Gassmann; Pascal Leprince; Guillaume Lebreton
Journal:  Gen Thorac Cardiovasc Surg       Date:  2018-01-10

Review 4.  Aortic regurgitation after transcatheter aortic valve implantation: mechanisms and implications.

Authors:  Barbara E Stähli; Willibald Maier; Roberto Corti; Thomas F Lüscher; Rolf Jenni; Felix C Tanner
Journal:  Cardiovasc Diagn Ther       Date:  2013-03

Review 5.  Current status and future perspectives of prosthetic valve selection for aortic valve replacement.

Authors:  Hiroshi Furukawa; Kazuo Tanemoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-05-31

6.  Structural valve deterioration after aortic valve replacement with Medtronic freestyle stentless porcine aortic root bioprostheses.

Authors:  Hidefumi Nishida; Tatsuhiko Komiya; Genichi Sakaguchi; Takeshi Shimamoto
Journal:  J Card Surg       Date:  2013-10-22       Impact factor: 1.620

Review 7.  Echocardiographic Assessment of Heart Valve Prostheses.

Authors:  Chiara Sordelli; Sergio Severino; Luigi Ascione; Pasquale Coppolino; Pio Caso
Journal:  J Cardiovasc Echogr       Date:  2014 Oct-Dec

Review 8.  Long-term Transcatheter Aortic Valve Durability.

Authors:  Giuliano Costa; Enrico Criscione; Denise Todaro; Corrado Tamburino; Marco Barbanti
Journal:  Interv Cardiol       Date:  2019-05-21

9.  Reinterventions after freestyle stentless aortic valve replacement: an assessment of procedural risks.

Authors:  Adriaan W Schneider; Mark G Hazekamp; Michel I M Versteegh; Arend de Weger; Eduard R Holman; Robert J M Klautz; Eline F Bruggemans; Jerry Braun
Journal:  Eur J Cardiothorac Surg       Date:  2019-12-01       Impact factor: 4.191

10.  Commentary: Stentless valve for bicuspid aortic valve replacement: Some answers just lead to more questions.

Authors:  Charles M Wojnarski; Robert J Moraca
Journal:  JTCVS Open       Date:  2021-11-06
View more