Literature DB >> 22965980

Clampless off-pump versus conventional coronary artery revascularization: a propensity score analysis of 788 patients.

Jochen Börgermann1, Kavous Hakim, André Renner, Amin Parsa, Anas Aboud, Tobias Becker, Marc Masshoff, Armin Zittermann, Jan Fritz Gummert, Oliver Kuss.   

Abstract

BACKGROUND: This study aimed to assess if clampless off-pump coronary artery bypass grafting (CABG) decreases risk-adjusted mortality, stroke rate, and morbidity in unselected patients in comparison to conventional CABG. METHODS AND
RESULTS: Between July 2009 and November 2010, data of 1282 consecutive patients undergoing isolated CABG were prospectively recorded. In 30.8% (n=395), clampless off-pump revascularization was used, either with the PAS-Port automated central venous anastomosis system (n=310) or as total arterial revascularization without central anastomoses (n=85). Propensity score (PS) matching was performed based on 15 preoperative risk variables to correct for selection bias. In-hospital mortality and stroke rate as primary end point, as well as major complications and follow-up outcome of clampless off-pump (lessOPCAB) and conventional CABG (cCABG) were compared in 394 matched patient pairs (total: 788 patients). The clampless off-pump technique decreased the in-hospital rate of death (odds ratio, 0.25; 95% confidence interval, 0.05-1.18, P=0.080) and stroke (odds ratio, 0.36; 95% confidence interval, 0.13-0.99, P=0.048) significantly. Complications such as low cardiac output syndrome, prolonged ventilation and rethoracotomy were also reduced by lessOPCAB. Over a 2-year follow-up period overall survival, cerebrovascular and major adverse event rate were significantly lower in the lessOPCAB group, while the repeat revascularization rate was comparable.
CONCLUSIONS: In a retrospective PS-matched analysis, clampless off-pump CABG lowers mortality, stroke rate and other morbidity in an unselected group of patients with coronary artery disease.

Entities:  

Mesh:

Year:  2012        PMID: 22965980     DOI: 10.1161/CIRCULATIONAHA.111.084285

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  16 in total

Review 1.  Contemporary coronary artery bypass grafting.

Authors:  David P Taggart
Journal:  Front Med       Date:  2014-11-03       Impact factor: 4.592

Review 2.  Propensity Score: an Alternative Method of Analyzing Treatment Effects.

Authors:  Oliver Kuss; Maria Blettner; Jochen Börgermann
Journal:  Dtsch Arztebl Int       Date:  2016-09-05       Impact factor: 5.594

3.  Incidence of perioperative stroke in clampless aortic anastomosis during off-pump coronary artery bypass grafting.

Authors:  Francesco Formica; Giuseppe Tata; Gurmeet Singh; Serena Mariani; Stefano D'Alessandro; Luigi Amerigo Messina; Fabio Sangalli; Giovanni Paolini
Journal:  Heart Vessels       Date:  2017-12-12       Impact factor: 2.037

4.  Avoiding aortic clamping during coronary artery bypass grafting reduces postoperative stroke.

Authors:  Emmanuel Moss; John D Puskas; Vinod H Thourani; Patrick Kilgo; Edward P Chen; Bradley G Leshnower; Omar M Lattouf; Robert A Guyton; Kathryn E Glas; Michael E Halkos
Journal:  J Thorac Cardiovasc Surg       Date:  2014-09-16       Impact factor: 5.209

Review 5.  Off-Pump Coronary Artery Bypass Grafting; is it Still Relevant?

Authors:  Chima K P Ofoegbu; Rodgers M Manganyi
Journal:  Curr Cardiol Rev       Date:  2022

Review 6.  Strategies for the coronary surgeon to remain "competitive and co-operative" in the PCI era.

Authors:  George Jose Valooran; Shiv Kumar Nair; Krishnan Chandrasekharan
Journal:  Indian Heart J       Date:  2015-07-08

7.  A propensity score analysis on the effect of on-pump versus off-pump coronary artery bypass grafting for patients with coronary artery disease.

Authors:  Peng Liu; Fei Wang; Shiyan Ren; Fan Lin; Yuguang Yang; Xueqiang Fan; Guang Sun; Xia Zheng; Jiangtao Liu; Jing Yuan; Zhidong Ye
Journal:  J Thorac Dis       Date:  2014-06       Impact factor: 2.895

8.  Morphological Evaluation of Proximal Anastomosis by PAS-Port(®) System in Patients with Long-Term Patent Grafts.

Authors:  Muneyasu Kawasaki; Takeshiro Fujii; Masanori Hara; Yuki Sasaki; Tomoyuki Katayanagi; Shinnosuke Okuma; Yoshinori Watanabe
Journal:  Ann Thorac Cardiovasc Surg       Date:  2014-07-30       Impact factor: 1.520

9.  Partially anaortic clampless off-pump coronary artery bypass prevents neurologic injury compared to on-pump coronary surgery: a propensity score-matched study on 286 patients.

Authors:  Carlo Bassano; Emanuele Bovio; Floriano Uva; Simona Iacobelli; Nicola Iasevoli; Andrea Farinaccio; Giovanni Ruvolo
Journal:  Heart Vessels       Date:  2015-10-23       Impact factor: 2.037

10.  On- or Off-pump Coronary Artery Bypass Surgery. Is the Debate Settling Down?

Authors:  Walter J Gomes; Gianni D Angelini
Journal:  Braz J Cardiovasc Surg       Date:  2019-08-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.