Literature DB >> 22959017

The development of DNA-based quartz crystal microbalance integrated with isothermal DNA amplification system for human papillomavirus type 58 detection.

Preeda Prakrankamanant1, Chanvit Leelayuwat, Chamras Promptmas, Temduang Limpaiboon, Surasak Wanram, Prinya Prasongdee, Chamsai Pientong, Jureerat Daduang, Patcharee Jearanaikoon.   

Abstract

To address the effect of dramatic change in temperature and viscosity during PCR process on quartz crystal microbalance (QCM) sensor and to increase the sensitivity, isothermal amplification was employed in the system. We combined loop-mediated isothermal amplification (LAMP) technique with QCM, called as LAMP-QCM, for detection of high-risk human papillomavirus viral DNA type 58 (HPV-58) which is commonly found in Asian women. The liquid-phase LAMP-QCM prototype comprised the frequency counter, a temperature control device and housing of the quartz crystal with polished gold electrodes on both sides. QCM detection signal was monitored in real-time based on an avidin-biotin binding between avidin coated QCM surface and specific biotinylated LAMP products. Analytical performance was evaluated for precision, sensitivity and specificity. A plasmid clone containing the HPV-58 sequence was diluted from 10(6) to 1 copy and used for detection limit. Cut-off value was estimated at 28.8 Hz from negative viral template. The system could detect 100 copies with Δf at 34.0±3.6 Hz compared to 1000 copies detected by conventional LAMP. No cross-reaction was observed with other HPV types. The HPV-58 detection was compared among LAMP-QCM, conventional LAMP and nested PCR in 50 cervical cancer tissues. The positive rate of LAMP-QCM was higher than that of conventional LAMP with 100% sensitivity and 90.5% specificity. The integrated LAMP-QCM system has improved the detection limit up to ten times compared to conventional LAMP with less-time consuming.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22959017     DOI: 10.1016/j.bios.2012.07.033

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  9 in total

Review 1.  Acoustic Biosensors and Microfluidic Devices in the Decennium: Principles and Applications.

Authors:  Minu Prabhachandran Nair; Adrian J T Teo; King Ho Holden Li
Journal:  Micromachines (Basel)       Date:  2021-12-26       Impact factor: 2.891

Review 2.  Bottom-Up Synthesis and Sensor Applications of Biomimetic Nanostructures.

Authors:  Li Wang; Yujing Sun; Zhuang Li; Aiguo Wu; Gang Wei
Journal:  Materials (Basel)       Date:  2016-01-18       Impact factor: 3.623

3.  Assessing the performance of a Loop Mediated Isothermal Amplification (LAMP) assay for the detection and subtyping of high-risk suptypes of Human Papilloma Virus (HPV) for Oropharyngeal Squamous Cell Carcinoma (OPSCC) without DNA purification.

Authors:  Mitchell G Rohatensky; Devon M Livingstone; Paul Mintchev; Heather K Barnes; Steven C Nakoneshny; Douglas J Demetrick; Joseph C Dort; Guido van Marle
Journal:  BMC Cancer       Date:  2018-02-08       Impact factor: 4.430

4.  Development of a LAMP assay using a portable device for the real-time detection of cotton leaf curl disease in field conditions.

Authors:  Amna Rafiq; Waqas Rafique Ali; Muhammad Asif; Nasim Ahmed; Waheed S Khan; Shahid Mansoor; Sadia Zafar Bajwa; Imran Amin
Journal:  Biol Methods Protoc       Date:  2021-05-06

5.  Aerosol-Cell Exposure System Applied to Semi-Adherent Cells for Aerosolization of Lung Surfactant and Nanoparticles Followed by High Quality RNA Extraction.

Authors:  Mélanie M Leroux; Romain Hocquel; Kevin Bourge; Boštjan Kokot; Hana Kokot; Tilen Koklič; Janez Štrancar; Yaobo Ding; Pramod Kumar; Otmar Schmid; Bertrand H Rihn; Luc Ferrari; Olivier Joubert
Journal:  Nanomaterials (Basel)       Date:  2022-04-15       Impact factor: 5.719

6.  Sequence-specific DNA detection at 10 fM by electromechanical signal transduction.

Authors:  Leyla Esfandiari; Michael Lorenzini; Gayane Kocharyan; Harold G Monbouquette; Jacob J Schmidt
Journal:  Anal Chem       Date:  2014-09-19       Impact factor: 6.986

7.  Ion-channel genosensor for the detection of specific DNA sequences derived from Plum Pox Virus in plant extracts.

Authors:  Kamila Malecka; Lech Michalczuk; Hanna Radecka; Jerzy Radecki
Journal:  Sensors (Basel)       Date:  2014-10-09       Impact factor: 3.576

8.  Quartz crystal microbalances (QCM) are suitable for real-time dosimetry in nanotoxicological studies using VITROCELL®Cloud cell exposure systems.

Authors:  Yaobo Ding; Patrick Weindl; Anke-Gabriele Lenz; Paula Mayer; Tobias Krebs; Otmar Schmid
Journal:  Part Fibre Toxicol       Date:  2020-09-16       Impact factor: 9.400

Review 9.  A Review of Piezoelectric and Magnetostrictive Biosensor Materials for Detection of COVID-19 and Other Viruses.

Authors:  Fumio Narita; Zhenjin Wang; Hiroki Kurita; Zhen Li; Yu Shi; Yu Jia; Constantinos Soutis
Journal:  Adv Mater       Date:  2020-11-24       Impact factor: 32.086

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.