Literature DB >> 22957771

Visual performance comparison between contact lens-based pinhole and simultaneous vision contact lenses.

Santiago García-Lázaro1, César Albarrán-Diego, Teresa Ferrer-Blasco, Hema Radhakrishnan, Robert Montés-Micó.   

Abstract

BACKGROUND: The aim was to evaluate the visual performance provided with a contact lens-based pinhole design against a simultaneous vision multifocal contact lens.
METHODS: In a cross-over study at the University of Valencia, 22 presbyopic patients were evaluated using an artificial pupil fitted on the non-dominant eye and the simultaneous vision PureVision Multifocal contact lenses. After one month of contact lens wear, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m(2)). In addition, binocular distance visual acuity and binocular distance contrast sensitivity were examined under mesopic conditions (5 cd/m(2)).
RESULTS: Mean binocular distance visual acuity for pinhole and PureVision Multifocal were 0.02 ± 0.04 and 0.01 ± 0.04 logMAR under photopic conditions and 0.16 ± 0.06 and 0.12 ± 0.04 logMAR for binocular near visual acuity under mesopic conditions, respectively. No statistically significant differences were found between both types of lenses at distance for both lighting levels and intermediate distances (p > 0.05). There was a significant difference at near vision under photopic conditions (p = 0.03). Binocular distance contrast sensitivity revealed statistically significant differences between the pinhole system and PureVision Multifocal for six and 12 cpd (cycles per degree) spatial frequencies at the two luminance levels, while for near vision, differences were also significant for 18 cpd. Stereoacuity was better with PureVision Multifocal (127 ± 49.3 seconds of arc) compared with the pinhole lens (220.2 ± 32.3 seconds of arc, p = 0.004).
CONCLUSION: Pinhole and PureVision Multifocal contact lenses provide good binocular vision for distance and functional intermediate vision. Although it was better with the PureVision Multifocal, near vision was not satisfactory for either of the two contact lens options.
© 2012 The Authors. Clinical and Experimental Optometry © 2012 Optometrists Association Australia.

Entities:  

Mesh:

Year:  2012        PMID: 22957771     DOI: 10.1111/j.1444-0938.2012.00791.x

Source DB:  PubMed          Journal:  Clin Exp Optom        ISSN: 0816-4622            Impact factor:   2.742


  3 in total

1.  Impact of pupil transmission apodization on presbyopic through-focus visual performance with spherical aberration.

Authors:  Len Zheleznyak; HaeWon Jung; Geunyoung Yoon
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-01-03       Impact factor: 4.799

2.  Pupil diameter, working distance and illumination during habitual tasks. Implications for simultaneous vision contact lenses for presbyopia.

Authors:  Genís Cardona; Sílvia López
Journal:  J Optom       Date:  2015-10-09

3.  The prevalence and causes of visual impairment among ethnic Tujia adults in a rural community in China.

Authors:  Xiaojing Xiong; Danning Liu; Shenchun Liu; Mingxing Wu; Bainwen Zhan; Hao Wang; Xiyuan Zhou
Journal:  Medicine (Baltimore)       Date:  2020-11-13       Impact factor: 1.817

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.