April M Durant 1 , Patricia Sura , Barton Rohrbach , Mark W Bohling . Show Affiliations »
Abstract
OBJECTIVE: To report bronchoscopic placement of nitinol stents (Vet Stent-Trachea®) for improvement of end-stage clinical signs in dogs with tracheal collapse. STUDY DESIGN: Case series. SAMPLE POPULATION: Dogs (n = 18). METHODS: Medical records (January 1, 2004-October 31, 2008) were searched for dogs with a diagnosis of tracheal collapse; 18 dogs met inclusion criteria. Tracheal diameter was compared before and after stent deployment. Stent dimensions were compared after stent deployment and at radiographic follow-up. RESULTS: There was a significant difference in the minimum tracheal diameter when initial and post deployment tracheal diameters were compared (P = .003). Stent length was significantly shorter at follow-up when compared to post deployment measurements (P = .004). Owner assessment of outcome was available for all dogs with 11.1% mortality within 60 days. Complications were documented in 9 dogs. CONCLUSIONS: Use of a nitinol stent (Vet Stent-Trachea®) in dogs with end-stage tracheal collapse is associated with a fair to good outcome despite significant temporal stent fore shortening after bronchoscopic placement. © Copyright 2012 by The American College of Veterinary Surgeons.
OBJECTIVE: To report bronchoscopic placement of nitinol stents (Vet Stent-Trachea®) for improvement of end-stage clinical signs in dogs with tracheal collapse. STUDY DESIGN: Case series. SAMPLE POPULATION: Dogs (n = 18). METHODS: Medical records (January 1, 2004-October 31, 2008) were searched for dogs with a diagnosis of tracheal collapse; 18 dogs met inclusion criteria. Tracheal diameter was compared before and after stent deployment. Stent dimensions were compared after stent deployment and at radiographic follow-up. RESULTS: There was a significant difference in the minimum tracheal diameter when initial and post deployment tracheal diameters were compared (P = .003). Stent length was significantly shorter at follow-up when compared to post deployment measurements (P = .004). Owner assessment of outcome was available for all dogs with 11.1% mortality within 60 days. Complications were documented in 9 dogs . CONCLUSIONS: Use of a nitinol stent (Vet Stent-Trachea®) in dogs with end-stage tracheal collapse is associated with a fair to good outcome despite significant temporal stent fore shortening after bronchoscopic placement. © Copyright 2012 by The American College of Veterinary Surgeons.
Entities: Chemical
Species
Mesh: See more »
Substances: See more »
Year: 2012
PMID: 22957667 DOI: 10.1111/j.1532-950X.2012.01037.x
Source DB: PubMed Journal: Vet Surg ISSN: 0161-3499 Impact factor: 1.495