On the effect of body capacitance to ground in tetrapolar bioimpedance measurements.

Carles Aliau-Bonet1, Ramon Pallas-Areny.   

Abstract

Tetrapolar bioimpedance measurements on subjects have long been suspected of being affected by stray capacitance between the subjects' body and ground. This paper provides a circuit model to analyze that effect in the frequency range from 100 Hz to 1 MHz in order to identify the relevant parameters when impedance is measured by applying a voltage and measuring both the resulting current and the potential difference between two points on the surface of the volume conductor. The proposed model includes the impedance of each electrode and the input impedance of the differential voltage amplifier. When common values for the circuit parameters are assumed, the simplified model predicts: 1) a frequency-independent gain (scale factor) error; 2) inductive artifacts, that is, the measured impedance increases with increasing frequency and may include positive angle phases; and 3) resonance that can affect well below 1 MHz. In addition to the stray capacitance to ground, relevant parameters that determine those errors are the capacitance of the "low-current" electrode and the input capacitance of the differential voltage amplifier. Experimental results confirm those theoretical predictions and show effects from several additional resonances above 1 MHz that also depend on body capacitance to ground.

Mesh:

Year:  2012        PMID: 22955870     DOI: 10.1109/TBME.2012.2216880

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  3 in total

1.  A Bioimpedance Analysis Platform for Amputee Residual Limb Assessment.

Authors:  Joan E Sanders; Mark A Moehring; Travis M Rothlisberger; Reid H Phillips; Tyler Hartley; Colin R Dietrich; Christian B Redd; David W Gardner; John C Cagle
Journal:  IEEE Trans Biomed Eng       Date:  2015-11-19       Impact factor: 4.538

Review 2.  Wireless Body Sensor Communication Systems Based on UWB and IBC Technologies: State-of-the-Art and Open Challenges.

Authors:  Ivana Čuljak; Željka Lučev Vasić; Hrvoje Mihaldinec; Hrvoje Džapo
Journal:  Sensors (Basel)       Date:  2020-06-25       Impact factor: 3.576

3.  Smart Bioimpedance Spectroscopy Device for Body Composition Estimation.

Authors:  David Naranjo-Hernández; Javier Reina-Tosina; Laura M Roa; Gerardo Barbarov-Rostán; Nuria Aresté-Fosalba; Alfonso Lara-Ruiz; Pilar Cejudo-Ramos; Francisco Ortega-Ruiz
Journal:  Sensors (Basel)       Date:  2019-12-21       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.