Literature DB >> 22954544

Comparison of the 2006 and 2010 cardiac CT appropriateness criteria in a real-world setting.

Sula Mazimba1, Nakash Grant, Analkumar Parikh, Trupti Patel, Bhakti Dahale, Zurisadai Franco, Nathaniel Dittoe, Tushar Shah, Harvey S Hahn.   

Abstract

BACKGROUND: Coronary CT angiography (CCTA) is a relatively new technique whose role has yet to be fully defined. The initial appropriateness criteria (AC) guidelines published in 2006 have already been revised. There is paucity of data on the effect of the AC on the use of CCTA at academic centers and none for the private sector.
METHODS: All CCTA studies ordered at one institution (a large community hospital with internal medicine and cardiovascular training programs) from 2006 to 2008 were retrospectively evaluated, and the ordering indications were categorized per the published AC for both 2006 and 2010.
RESULTS: There were 384 studies, of which 243 were included in this study. The majority of the studies were ordered for chest pain (67.1% of patients). A significant proportion of studies (43.2%) were classified as inappropriate on the basis of the 2006 published criteria. Uncertain indications made up 39.1%, and appropriate indications were a minority. There was a significant regrading of appropriateness using the 2010 guidelines. Inappropriate testing remained similar at 48.1%, but uncertain cases decreased to only 2.8%, while appropriateness increased to 49.0% (P = .0001 for trend).
CONCLUSIONS: The updated 2010 AC guidelines for CCTA resulted in a significant reclassification of the indications for ordering CCTA from the previous 2006 guidelines. This shift in the AC reflects increased familiarity and confidence with this new technology across the imaging community. A large proportion of CCTA studies were ordered for inappropriate indications using both sets of criteria. Further research and enhanced education are needed to disseminate the appropriate role of CCTA in cardiovascular imaging.
Copyright © 2012 American College of Radiology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22954544     DOI: 10.1016/j.jacr.2012.04.016

Source DB:  PubMed          Journal:  J Am Coll Radiol        ISSN: 1546-1440            Impact factor:   5.532


  3 in total

1.  Evaluation of appropriateness of second-generation 320-row computed tomography for coronary artery disease.

Authors:  Daisuke Utsunomiya; Seitaro Oda; Hideaki Yuki; Megumi Yamamuro; Kenichi Tsujita; Yoshinori Funama; Morikatsu Yoshida; Masafumi Kidoh; Hisao Ogawa; Yasuyuki Yamashita
Journal:  Springerplus       Date:  2015-03-05

2.  The feasibility of 1-stop examination of coronary CT angiography and abdominal enhanced CT.

Authors:  Wei Fang; Cai-Hong Wang; Yi-Fan Yu; Li-Huan Wang; Dan-Hua Tang; Da-Bo Xu; Zuo-Yun Ding; Wen-Hao Gu
Journal:  Medicine (Baltimore)       Date:  2018-08       Impact factor: 1.889

3.  Appropriate utilization of cardiac computed tomography for the assessment of stable coronary artery disease.

Authors:  Michael Hammer; Muhtashim Mian; Levi Elhadad; Mary Li; Idan Roifman
Journal:  BMC Cardiovasc Disord       Date:  2021-03-26       Impact factor: 2.298

  3 in total