BACKGROUND:Everolimus-eluting stent (EES) reduces the risk of restenosis in elective percutaneous coronary intervention. However, the use of drug-eluting stent in patients with ST-segment elevation myocardial infarction (STEMI) is still controversial. Data regarding the performance of second-generation EES in this setting are scarce. We report the 1-year result of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) trial, comparing EES with bare-metal stents (BMS) in patients with STEMI. METHODS: This multicentre, prospective, randomised, all-comer controlled trial was done in 12 medical centres in three countries. Between Dec 31, 2008, and May 15, 2010, we recruited patients with STEMI up to 48 h after the onset of symptoms requiring emergent percutaneous coronary intervention. Patients were randomly assigned (ratio 1:1) to receive EES or BMS. Randomisation was in blocks of four or six patients, stratified by centre and centralised by telephone. Patients were masked to treatment. The primary endpoint was the patient-oriented combined endpoint of all-cause death, any recurrent myocardial infarction, and any revascularisation at 1 year and was analysed by intention to treat. The secondary endpoints of the study included the device-oriented combined endpoint of cardiac death, target vessel myocardial infarction or target lesion revascularisation, and rates of all cause or cardiac death, recurrent myocardial infarction, target lesion or target vessel revascularisation, stent thrombosis, device and procedure success, and major and minor bleeding. This trial is registered with ClinicalTrials.gov, number NCT00828087. FINDINGS: Of the 1504 patients randomised, 1498 patients were randomly assigned to receive EES (n=751) or BMS (n=747). The primary endpoint was similar in both groups (89 [11·9%] of 751 patients in the EES group vs 106 [14·2%] of 747 patients in the BMS group; difference -2·34 [95% CI -5·75 to 1·07]; p=0·19). Device-oriented endpoint (44 [5·9%] in the EES group vs 63 [8·4%] in the BMS group; difference -2·57 [95% CI -5·18 to 0·03]; p=0·05) did not differ between groups, although rates of target lesion and vessel revascularisation were significantly lower in the EES group (16 [2·1%] vs 37 [5·0%], p=0·003, and 28 [3·7%] vs 51 [6·8%], p=0·0077, respectively). Rates of all cause (26 [3·5%] for EES vs 26 [3·5%] for BMS, p=1·00) or cardiac death (24 [3·2%] for EES vs 21 [2·8%] for BMS, p=0·76) or myocardial infarction (10 [1·3%] vs 15 [2·0%], p=0·32) did not differ between groups. Stent thrombosis rates were significantly lower in the EES group (4 [0·5%] patients with definite stent thrombosis in the EES group vs 14 [1·9%] in the BMS group and seven [0·9%] patients with definite or probable stent thrombosis in the EES group vs 19 [2·5%] in the BMS group, both p=0·019). Although device success rate was similar between groups, procedure success rate was significantly higher in the EES group (731 [97·5%] vs 705 [94·6%]; p=0·0050). Finally, Bleeding rates at 1 year were comparable between groups (29 [3·9%] patients in the EES group vs 39 [5·2%] in the BMS group; p=0·19). INTERPRETATION: The use of EES compared with BMS in the setting of STEMI did not lower the patient-oriented endpoint. However, at the stent level both rates of target lesion revascularisation and stent thrombosis were reduced in recipients of EES. FUNDING: Spanish Heart Foundation.
RCT Entities:
BACKGROUND:Everolimus-eluting stent (EES) reduces the risk of restenosis in elective percutaneous coronary intervention. However, the use of drug-eluting stent in patients with ST-segment elevation myocardial infarction (STEMI) is still controversial. Data regarding the performance of second-generation EES in this setting are scarce. We report the 1-year result of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) trial, comparing EES with bare-metal stents (BMS) in patients with STEMI. METHODS: This multicentre, prospective, randomised, all-comer controlled trial was done in 12 medical centres in three countries. Between Dec 31, 2008, and May 15, 2010, we recruited patients with STEMI up to 48 h after the onset of symptoms requiring emergent percutaneous coronary intervention. Patients were randomly assigned (ratio 1:1) to receive EES or BMS. Randomisation was in blocks of four or six patients, stratified by centre and centralised by telephone. Patients were masked to treatment. The primary endpoint was the patient-oriented combined endpoint of all-cause death, any recurrent myocardial infarction, and any revascularisation at 1 year and was analysed by intention to treat. The secondary endpoints of the study included the device-oriented combined endpoint of cardiac death, target vessel myocardial infarction or target lesion revascularisation, and rates of all cause or cardiac death, recurrent myocardial infarction, target lesion or target vessel revascularisation, stent thrombosis, device and procedure success, and major and minor bleeding. This trial is registered with ClinicalTrials.gov, number NCT00828087. FINDINGS: Of the 1504 patients randomised, 1498 patients were randomly assigned to receive EES (n=751) or BMS (n=747). The primary endpoint was similar in both groups (89 [11·9%] of 751 patients in the EES group vs 106 [14·2%] of 747 patients in the BMS group; difference -2·34 [95% CI -5·75 to 1·07]; p=0·19). Device-oriented endpoint (44 [5·9%] in the EES group vs 63 [8·4%] in the BMS group; difference -2·57 [95% CI -5·18 to 0·03]; p=0·05) did not differ between groups, although rates of target lesion and vessel revascularisation were significantly lower in the EES group (16 [2·1%] vs 37 [5·0%], p=0·003, and 28 [3·7%] vs 51 [6·8%], p=0·0077, respectively). Rates of all cause (26 [3·5%] for EES vs 26 [3·5%] for BMS, p=1·00) or cardiac death (24 [3·2%] for EES vs 21 [2·8%] for BMS, p=0·76) or myocardial infarction (10 [1·3%] vs 15 [2·0%], p=0·32) did not differ between groups. Stent thrombosis rates were significantly lower in the EES group (4 [0·5%] patients with definite stent thrombosis in the EES group vs 14 [1·9%] in the BMS group and seven [0·9%] patients with definite or probable stent thrombosis in the EES group vs 19 [2·5%] in the BMS group, both p=0·019). Although device success rate was similar between groups, procedure success rate was significantly higher in the EES group (731 [97·5%] vs 705 [94·6%]; p=0·0050). Finally, Bleeding rates at 1 year were comparable between groups (29 [3·9%] patients in the EES group vs 39 [5·2%] in the BMS group; p=0·19). INTERPRETATION: The use of EES compared with BMS in the setting of STEMI did not lower the patient-oriented endpoint. However, at the stent level both rates of target lesion revascularisation and stent thrombosis were reduced in recipients of EES. FUNDING: Spanish Heart Foundation.
Authors: Giuseppe De Luca; Maurits T Dirksen; Christian Spaulding; Henning Kelbæk; Martin Schalij; Leif Thuesen; Bas van der Hoeven; Marteen A Vink; Christoph Kaiser; Carmine Musto; Tania Chechi; Gaia Spaziani; Luis Salvador Diaz de la Llera; Vincenzo Pasceri; Emilio Di Lorenzo; Roberto Violini; Harry Suryapranata; Gregg W Stone Journal: Clin Res Cardiol Date: 2014-04-01 Impact factor: 5.460
Authors: Giuseppe De Luca; Jeffrey Wirianta; Jae-Hwan Lee; Christoph Kaiser; Emilio Di Lorenzo; Harry Suryapranata Journal: J Thromb Thrombolysis Date: 2014-10 Impact factor: 2.300
Authors: Celso Kiyochi Takimura; Carlos Augusto Homem M Campos; Pedro Henrique Magualhães Craveiro Melo; Julliana Carvalho Campos; Paulo Sampaio Gutierrez; Thiago Francisco Costa Borges; Luciano Curado; Spero Penha Morato; Francisco Rafael Martins Laurindo; Pedro Alves Lemos Neto Journal: Arq Bras Cardiol Date: 2014-04-17 Impact factor: 2.000
Authors: Santanu Guha; Rishi Sethi; Saumitra Ray; Vinay K Bahl; S Shanmugasundaram; Prafula Kerkar; Sivasubramanian Ramakrishnan; Rakesh Yadav; Gaurav Chaudhary; Aditya Kapoor; Ajay Mahajan; Ajay Kumar Sinha; Ajit Mullasari; Akshyaya Pradhan; Amal Kumar Banerjee; B P Singh; J Balachander; Brian Pinto; C N Manjunath; Chandrashekhar Makhale; Debabrata Roy; Dhiman Kahali; Geevar Zachariah; G S Wander; H C Kalita; H K Chopra; A Jabir; JagMohan Tharakan; Justin Paul; K Venogopal; K B Baksi; Kajal Ganguly; Kewal C Goswami; M Somasundaram; M K Chhetri; M S Hiremath; M S Ravi; Mrinal Kanti Das; N N Khanna; P B Jayagopal; P K Asokan; P K Deb; P P Mohanan; Praveen Chandra; Col R Girish; O Rabindra Nath; Rakesh Gupta; C Raghu; Sameer Dani; Sandeep Bansal; Sanjay Tyagi; Satyanarayan Routray; Satyendra Tewari; Sarat Chandra; Shishu Shankar Mishra; Sibananda Datta; S S Chaterjee; Soumitra Kumar; Soura Mookerjee; Suma M Victor; Sundeep Mishra; Thomas Alexander; Umesh Chandra Samal; Vijay Trehan Journal: Indian Heart J Date: 2017-03-23