Literature DB >> 22951061

Three-dimensional workstation is useful for measuring the correct size of abdominal aortic aneurysm diameters.

Tsutomu Ihara1, Kimihiro Komori, Kiyohito Yamamoto, Masayoshi Kobayashi, Hiroshi Banno, Akio Kodama.   

Abstract

BACKGROUND: Abdominal aortic aneurysm diameter is usually measured by the maximum minor-axis diameter on axial computed tomography (CT). However, this "traditional" diameter may underestimate the real size, as the aorta is not always straight and the aneurysm shape is sometimes in the form of an ellipse along the cross section. Therefore, we measured maximum major-axis diameters using a three-dimensional (3D) workstation and compared them with the traditional maximum minor-axis diameters measured using thin-slice axial CT.
METHODS: CT data of 141 AAA patients (with fusiform aneurysms) were stored in a 3D workstation. These thin-slice CT images were reviewed on the 3D workstation to obtain curved multiplanar reconstruction images (CPR images). Using the CPR images, we measured the maximum major-axis and minor-axis diameters on CPR and the angle of the aneurysms to the body axis.
RESULTS: The mean traditional maximum minor-axis diameter was 51.2 ± 8.2 mm, whereas the mean maximum major-axis diameter on CPR was 54.7 ± 10.1 mm. Sixty eight patients had a mean aneurysm size of <50 mm when measured by the traditional minor-axis diameter. Among these patients, five (7.4%) had a major-axis diameter >55 mm on CPR.
CONCLUSION: The measurement of the traditional maximum minor-axis diameter of aneurysms is useful in the case of most patients. However, the traditional maximum minor-axis diameter may underestimate the real aneurysmal diameter, particularly in patients with an ellipse-shaped aneurysm. The maximum major-axis diameter as measured using CPR images is effective for representing the real aneurysmal size.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22951061     DOI: 10.1016/j.avsg.2012.03.009

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  9 in total

Review 1.  CT angiography in the diagnosis of cardiovascular disease: a transformation in cardiovascular CT practice.

Authors:  Zhonghua Sun; Mansour Al Moudi; Yan Cao
Journal:  Quant Imaging Med Surg       Date:  2014-10

Review 2.  The Mystery of the Z-Score.

Authors:  Alexander E Curtis; Tanya A Smith; Bulat A Ziganshin; John A Elefteriades
Journal:  Aorta (Stamford)       Date:  2016-08-01

Review 3.  Repair of abdominal aortic aneurysms: preoperative imaging and evaluation.

Authors:  David K Hu; George T Pisimisis; Rahul A Sheth
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

4.  Non-contrast MR angiography using three-dimensional balanced steady-state free-precession imaging for evaluation of stenosis in the celiac trunk and superior mesenteric artery: a preliminary comparative study with computed tomography angiography.

Authors:  Patricia P Cardia; Thiago J Penachim; Adilson Prando; Ulysses S Torres; Giuseppe D'Ippólito
Journal:  Br J Radiol       Date:  2017-06-07       Impact factor: 3.039

5.  Non-invasive volumetric assessment of aortic atheroma: a core laboratory validation using computed tomography angiography.

Authors:  Muhammad Hammadah; Mohammed Qintar; Steven E Nissen; Julie St John; Saqer Alkharabsheh; Motunrayo Mobolaji-Lawal; Femi Philip; Kiyoko Uno; Yu Kataoka; Brett Babb; Roman Poliszczuk; Samir R Kapadia; E Murat Tuzcu; Paul Schoenhagen; Stephen J Nicholls; Rishi Puri
Journal:  Int J Cardiovasc Imaging       Date:  2015-05-12       Impact factor: 2.357

6.  Relationship between the distal migration and length of the distal landing zone after endovascular aneurysm repair (EVAR).

Authors:  Tsutomu Ihara; Kimihiro Komori; Hiroshi Banno; Akio Kodama; Kiyohito Yamamoto; Masayuki Sugimoto
Journal:  Surg Today       Date:  2014-12-25       Impact factor: 2.549

7.  Low Serum Levels of EPA are Associated with the Size and Growth Rate of Abdominal Aortic Aneurysm.

Authors:  Tatsuro Aikawa; Tetsuro Miyazaki; Kazunori Shimada; Yurina Sugita; Megumi Shimizu; Shohei Ouchi; Tomoyasu Kadoguchi; Yasutaka Yokoyama; Tomoyuki Shiozawa; Masaru Hiki; Shuhei Takahashi; Hamad Al Shahi; Shizuyuki Dohi; Atsushi Amano; Hiroyuki Daida
Journal:  J Atheroscler Thromb       Date:  2017-03-22       Impact factor: 4.928

8.  Performance of a deep learning tool to detect missed aortic dilatation in a large chest CT cohort.

Authors:  Maurice Pradella; Rita Achermann; Jonathan I Sperl; Rainer Kärgel; Saikiran Rapaka; Joshy Cyriac; Shan Yang; Gregor Sommer; Bram Stieltjes; Jens Bremerich; Philipp Brantner; Alexander W Sauter
Journal:  Front Cardiovasc Med       Date:  2022-08-22

9.  Low correlation between biometric parameters, cardiovascular risk factors and aortic dimensions by computed tomography coronary angiography.

Authors:  Ernesto Forte; Bruna Punzo; Marco Salvatore; Erica Maffei; Stefano Nistri; Carlo Cavaliere; Filippo Cademartiri
Journal:  Medicine (Baltimore)       Date:  2020-08-28       Impact factor: 1.817

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.